Gas -Oriental GB – Gas Teppanyaki Jumbo Grill
FRM-PDE-03-04
6.
Before installing Gas Teppanyaki Jumbo Grill, make sure that it is set for the gas and pressure
(see Technical Data Plates). Consult the paragraph “Gas Conversion”.
7.
Connect Gas Teppanyaki Jumbo Grill to gas supply using solid fittings or flexible steel pipes with
suitable sections related to nominal power and length.
8.
Check whether the flexible pipes does not pass or near hot surfaces, put under stress and
traction, contact with sharp edges, or other things that could damage the pipe.
9.
Install quick ON – OFF valve between the gas mains and each single appliance where easy to
reach.
10.
After install Gas Teppanyaki Jumbo Grill safely, take a pressure test the whole gas circuit by
using leak finder spray or non-corrosive foams.
11.
The Gas Teppanyaki Jumbo Grill is equipped with ISO 7/ 1 screw thread, gas connection of ¾
inches diameter and suitable adapter for ISO 228/ 1 G screw thread gas connection are provided
together with the appliance according to destined countries.
Checking Gas Pressure and Nominal Heat Input
At the first installation, specialized technician must control Gas Teppanyaki Jumbo Grill nominal heat
input, maintenance, and gas conversion. DO NOT improve Gas Teppanyaki Jumbo Grill performance
and increase nominal heat affirmed by the manufacturer. Control heat input by using gas counter and
chronometer. Measure the exact amount of gas flow per unit of time which consumed by the appliance
at maximum power. Compare the measurement to the consumption data on Data Technical Table 1, ±
5% tolerance is allowed. When you are measuring top deviations, carefully check the diameters and the
quality of installed injectors and gas main pressure. If you want to measure the main pressure while
Gas Teppanyaki Jumbo Grill is ON and using a pressure gauge for liquids (for example U manometer,
with minimum resolution 0.1 mbar), please follow direction below:
1. Connect flexible pipe “E” from Manometer “M” to inlet pressure point “C” after unscrewing its
cap.
2. Measure the inlet pressure. If the value is not between minimum and maximum as indicated in
Table 5, the appliance cannot work properly and the gas company must be informed to find out
the problem of supply pressure.
3. If necessary, a pressure regulator must be installed. Once the pressure has been measured,
disconnect flexible pipe “E”, retighten the screw cap of the inlet pressure point “C”. Restore all
components inversely.
NAYATI
22
20150917