background image

6

NAVMAN R100 User Manual

Wiring Connection

• Keep electrical and transducer cables away

from alternator or other noise generating
electrical cables. Avoid connecting the
instrument to power circuits that share
loads with ignition, alternators, inverters and
radio transmitters. Electrical power supply
connections should always  be as short as
possible.

• Connect the red wire to the positive supply

via a 1 amp fuse or a 1 amp circuit breaker.
Connect the black wire to the electrical
ground. A 1 amp fuse will provide protection
for up to five 100 series instruments.

• The NAVMAN R100 repeater is intended to

be connected with a number of other 100
series instruments or to other instruments
that output NMEA 0183 data.

1A Fuse

+12 VDC

White

White

Yellow

Yellow

Blue

Blue

Green

Black

Black

Red

Red

Green

Ground

Connecting Multiple Repeaters

Multiple repeaters may be connected so that
repeaters can be placed in different locations or
to allow the simultaneous display of a greater
number of functions.

Yellow

NMEA Input

Black

Ground

Blue

NMEA Input

Green

NMEA Input

White

NMEA Input

Red

+12 VDC

Summary of Contents for REPEAT 100

Page 1: ...REPEAT NAVMAN NAVMAN...

Page 2: ...tion 4 Installation 5 Location 5 Mounting 5 Wiring Connection 6 Connecting Multiple Repeaters 6 Connecting Multiple Instruments 7 Setup 8 Data Search Mode 8 Operation 8 Changing Functions 8 Backlighti...

Page 3: ...0183 format VHW VLW MTW DPT DBT DBK DBS MWV VPW HDG HDT AAM APB BWC RMA RMB RMC VTG XTE Introduction The NAVMAN R100 is a high quality digital data repeater Features include Up to 4 seperate NMEA ins...

Page 4: ...4 4 5mm 1 75 30mm 1 2 112mm 4 4 24mm 1 56mm 2 2 35mm 1 4 Mounting The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole throu...

Page 5: ...ct the black wire to the electrical ground A 1 amp fuse will provide protection for up to five 100 series instruments The NAVMAN R100 repeater is intended to be connected with a number of other 100 se...

Page 6: ...3 1 Green Black Blue Red Black Blue Red 1A Fuse 12 VDC Black Blue Red Ground Note Wire colours refer to solid wires only Output wires from Wind Speed Depth can connect to Repeater inputs in any order...

Page 7: ...TH TRIP DISTANCE TRIP DISTANCE TRIP DISTANCE Setup Data Search Mode The NAVMAN R100 has four individual data inputs After making the initial connection to the NAVMAN R100 or after making any additiona...

Page 8: ...To enter this mode hold down the key and then switch on the power The instrument will remain in this mode even when power is switched off Repeat this procedure to exit simulation mode At power up if a...

Page 9: ...EA Functions Data can be displayed from other NMEA instruments COURSE OVER GROUND CROSS TRACK ERROR SPEED OVER GROUND TEMPERATURE DISTANCE TO WAYPOINT WIND SPEED BEARING TO WAYPOINT WIND DIRECTION COM...

Page 10: ...en NMEA instrument en afronding van de Data Search Mode is het mogelijk de R100 NMEA setup Mode op te starten Druk en houdt de en toets beiden 7 seconden ingedrukt om in de NMEA set up Mode te komen 1...

Page 11: ...e l l a r a P s m s m d n i v l l i t t l l e l l a r a p t r a F s m n e o t n e i v l a a l e l a r a p d a d i c o l e V W P V 0 4 3 c i t e n g a m s e e r g e d g n i d a e H s e u q i t n g a m...

Reviews:

Related manuals for REPEAT 100