Installation

Location

The NAVMAN R100 is designed for above or
below deck installation.  Select a position that is:

• At least 300mm from a compass

• At least 500mm from any radio

• Easy to read by the helmsman and crew

• Protected from physical damage

• Accessible to electrical cable connections

112mm

(4.4”)

4.5mm

(1.75”)

30mm

(1.2”)

112mm

(4.4”)

24mm

(1”)

56mm

(2.2”)

35mm

(1.4”)

Mounting

The mounting surface must be flat.  Use the
template to set the centre of the fixing hole.

• Drill a  32mm (1.25”) diameter mounting

hole through the bulkhead.

• Remove the fixing nut. Peel the protective

paper off the foam gasket and attach the
gasket to the rear of the instrument.

• Insert the instrument through the bulkhead.

Hand tighten the nut and then finally tighten
with a spanner. Do not over tighten so that
the water sealing ability of the gasket is
damaged.

Summary of Contents for REPEAT 100

Page 1: ...REPEAT NAVMAN NAVMAN...

Page 2: ...tion 4 Installation 5 Location 5 Mounting 5 Wiring Connection 6 Connecting Multiple Repeaters 6 Connecting Multiple Instruments 7 Setup 8 Data Search Mode 8 Operation 8 Changing Functions 8 Backlighti...

Page 3: ...0183 format VHW VLW MTW DPT DBT DBK DBS MWV VPW HDG HDT AAM APB BWC RMA RMB RMC VTG XTE Introduction The NAVMAN R100 is a high quality digital data repeater Features include Up to 4 seperate NMEA ins...

Page 4: ...4 4 5mm 1 75 30mm 1 2 112mm 4 4 24mm 1 56mm 2 2 35mm 1 4 Mounting The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole throu...

Page 5: ...ct the black wire to the electrical ground A 1 amp fuse will provide protection for up to five 100 series instruments The NAVMAN R100 repeater is intended to be connected with a number of other 100 se...

Page 6: ...3 1 Green Black Blue Red Black Blue Red 1A Fuse 12 VDC Black Blue Red Ground Note Wire colours refer to solid wires only Output wires from Wind Speed Depth can connect to Repeater inputs in any order...

Page 7: ...TH TRIP DISTANCE TRIP DISTANCE TRIP DISTANCE Setup Data Search Mode The NAVMAN R100 has four individual data inputs After making the initial connection to the NAVMAN R100 or after making any additiona...

Page 8: ...To enter this mode hold down the key and then switch on the power The instrument will remain in this mode even when power is switched off Repeat this procedure to exit simulation mode At power up if a...

Page 9: ...EA Functions Data can be displayed from other NMEA instruments COURSE OVER GROUND CROSS TRACK ERROR SPEED OVER GROUND TEMPERATURE DISTANCE TO WAYPOINT WIND SPEED BEARING TO WAYPOINT WIND DIRECTION COM...

Page 10: ...en NMEA instrument en afronding van de Data Search Mode is het mogelijk de R100 NMEA setup Mode op te starten Druk en houdt de en toets beiden 7 seconden ingedrukt om in de NMEA set up Mode te komen 1...

Page 11: ...e l l a r a P s m s m d n i v l l i t t l l e l l a r a p t r a F s m n e o t n e i v l a a l e l a r a p d a d i c o l e V W P V 0 4 3 c i t e n g a m s e e r g e d g n i d a e H s e u q i t n g a m...

Reviews:

Related manuals for REPEAT 100