  HFC-2    Installation Instructions 

 

- 11 - 

 

Note: Fix the feet tightly with bolts after the complete assembly. 

5. Connection and Lightning-Protection   

5.1

 Connection and Lightning-Protection:

 

 

Max number of collector in series: 10units

 

Mark

Please make sure the effective grounding to prevent lightning. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for HFC-2

Page 1: ...HFC 2 Installation Instructions 0 HFC 2 Installation Instructions...

Page 2: ...Slope Roof 4 2 Flat Roof 5 Connection and lightning protection 14 5 1 Connection and lightning protection 14 5 2 Collector coupling demonstration 15 5 3Pressure drop Curve 15 6 Solar System Demonstra...

Page 3: ...ow rate per collector 90liter hour Max volume flow rate per collector 1200liter hour Collector orientation for test vert Maximum operation pressure 6bar Testing pressure 9bar Heat transfer fluid Glyco...

Page 4: ...when glass broken 2 2 Under no circumstances are the collector to be left exposed to the sun over a long period before the system installation was completed Avoid high temperature of empty collector t...

Page 5: ...HFC 2 Installation Instructions 4 3 Structure and Dimensions Frame Heat Pipe Vacuum Tube CPC Reflector Glass Inlet Outlet...

Page 6: ...ip firstly and then use a pistol to dig into to take out B Aluminum rivet 3 2 11 and finally move glass together with glass frame Assembly Put on the glass together with glass frame Note the sealing s...

Page 7: ...tude Roof load shall withstand collector weight Make sure no cover around installation area Installation is divided into 4 1 Slope roof on tile 4 2 Flat roof 4 3 Color coated steel tile installation 4...

Page 8: ...es according to the A B C size and fix the brace to the roof Please choose the different fix ways according to the roof material wooden screws or anchors 4 1 1 2 Please put the bottom of screw to trac...

Page 9: ...well installed brace make the difference of the top and down horizontal bar See below photo It is better to add rubber spacer below horizontal bar to keep roof smoothly 4 1 3 Collector installation P...

Page 10: ...Flat roof installation Please choose the correct installation angle depends on the local latitude Adjustable angle 28 35 42 50 Front leg Stands higher stands lower horizontal bar top horizontal bar do...

Page 11: ...below photo the screw distance between horizontal bar is 1000mm Above shows 2sets solar collector in series The horizontal bar size should be 2200mm when 2pcs solar collector in series The horizontal...

Page 12: ...the feet tightly with bolts after the complete assembly 5 Connection and Lightning Protection 5 1 Connection and Lightning Protection Max number of collector in series 10units Mark Please make sure t...

Page 13: ...llation Instructions 12 5 2 Collector Coupling Demonstration Collector array with 20m2 5 3 Pressure drop Curve of Collector Pressure drop in Pa 0 100 200 300 400 500 600 700 0 100 200 300 400 500 Flow...

Page 14: ...the storage water tank below coil acts as heat exchanger to get energy from the solar collectors to heat water upper coil acts as heat exchanger from other normal heating solutions like Gas Oil boiler...

Page 15: ...ne way Pressure Air vent Security Setter Manual Valve valve valve gauge valve valve inline valve 6 4 Multi function Combined System It achieves consumption water heating and swimming pool heating in o...