7. Specifications

Chip set manufacturer/type u-blox5 GPS & GALILEO SuperSense

®

Channels

50 channels

Sensitivity

-160dBm

Frequency  

L1, 1575.42MHz

C/A Code

1.023MHz chip rate

Target precisions:
Position Horizontal

2.5m CEP, 5.0m SEP or SBAS 2.0m CEP, 3.0m SEP

Time 

1 microsecond synchronized with GPS time

Speed

0.1m/sec. 95% (SA off)

Date:

WGS-84

Protocol:

NMEA-0183 V3.01 GGA, GSA, GSV, RMC, VTG

Detection rates:
Hot start  

3.5s average (with ephemerides and almanac)

Warm start  

25s average (with ephemeredes, but without almanac)

Cold start  

30s average (neither ephemerides nor almanac)

Re-Acquisition

1s average (recovery time after interruption)

UP-DATE Rate:

4Hz

Dynamic prerequisites:
Acceleration limit  

smaller than 4g

Height limit  

18,000 meters (60000 feet) maximal

Speed limit  

515 meter/sec. (1000 knots) maximal

Performance:
Power supply

5 Volt via USB

Connection:

USB

Operating temperature:

-40°C ~ +85°C

Dimensions:

65 mm x 45 mm x 22 mm

 

8. Certificate

CE
FC

Summary of Contents for NL-402U

Page 1: ...NL 402U Operation manual 60095 a...

Page 2: ...TERIES IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED WITH THE PRODUCT PRECAUTIONS REGARDING DIRECT SUNLIGHT Make sure the unit is not exposed to very high humidity and te...

Page 3: ...ut Satfix 3 Application environment The NL 402U can be used as a USB GPS receiver under Windows 2000 XP Vista The corresponding driver is available on the CD ROM 4 Functional test with u Center 5 1 In...

Page 4: ...age console 7 NMEA text console As seen below you can set up your u Center by yourself Everything important can be connected and displayed immediately The green bars at the bottom of the picture show...

Page 5: ...is deactivated in the default setup That is not to say that by using these correction values the location determination will become better The users must decide for themselves if they want to use this...

Page 6: ...rns green and the messages SEND CANCEL and DONE are displayed This finishes the process Further information to the u Center can be found in the u blox documentation under http www u blox com products...

Page 7: ...fect was an external cause water damage fall over voltage or the wrong handling of the unit Failures are often the result of little causes It is not always necessary to exchange the product immediatel...

Page 8: ...SA GSV RMC VTG Detection rates Hot start 3 5s average with ephemerides and almanac Warm start 25s average with ephemeredes but without almanac Cold start 30s average neither ephemerides nor almanac Re...

Page 9: ...ou will be charged a connection fee for a telephone call to Germany Berlin in accordance with the connection fee overview of your telephone service provider Callers from Germany who subscribed to a na...

Page 10: ...gful re usage of electronic waste helps to deal with natural resources more economically In addition re using electronic waste contributes to the preservation of the environment and human health Addit...

Reviews: