background image

8        Operating the Water Heater

3.2    Adjusting the Water Temperature

WARNING

Before adjusting the water temperature, read “To prevent 
burns:” on page 4 carefully. Water above 120 °F can cause 
instant scalding, severe burns, or death.

The water heater is set to 120 °F (49 °C) by default. To adjust the 
water temperature:

1.  Make sure that all hot water faucets are closed, and ensure that 

the internal circulator and any external circulating pumps are 
off.

Note

If a hot water faucet is open, you can adjust the 
temperature only from 98-110 °F (37-43 °C).

2.  Press the + (Up) or – (Down) buttons until the desired 

temperature appears on the display. You can adjust the 
temperature while the display is flashing. Once the display 
stops flashing, the temperature setting is stored.

Note

The water heater will retain your settings during 
a power outage.

You can adjust the temperature by the below 10-degree 
increments, depending on the temperature range:

Temperature range

Adjusting the water 
temperature

98 °F-120 °F (Fahrenheit mode)
36 °C-50 °C (Celsius mode)

1 °F or 0.5 °C increments

120 °F-140 °F (Fahrenheit 
mode)
50 °C-60 °C (Celsius mode)

Press for 2 seconds to adjust in 
5 °F or 2 °C increments

The water heater will not provide hot water instantly at the hot 
water faucet unless a recirculation line has been installed from the 
furthest fixture back to the water heater. For “A” models, the unit 
must be set to “external recirculation” mode.

3.1    Turning the Water Heater On or Off

To turn the water heater on or off, press the Power button.

When the power is on, the temperature will appear on the front 
panel display.

3.    Operating the Water Heater

Summary of Contents for NPE-150S

Page 1: ...3 1 NFPA 54 and or CSA B149 1 Natural Gas and Propane Installation Code When applicable the installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 and or CAN CSA Z240 MH Series Mobile Homes Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required The wetted surface of this product contac...

Page 2: ...er Temperature 8 3 3 Viewing Basic Information 9 3 4 Resetting the Water Heater 9 4 Maintaining the Water Heater 10 4 1 Cleaning the Water Heater 10 4 2 Draining the Water Heater 10 4 3 Flushing the Heat Exchanger 11 4 4 Cleaning the Inlet Water Filter and Recirculation Inlet Filter 12 4 5 Cleaning the Air Intake Filter 13 4 6 Protecting the Water Heater from Freezing 14 5 Troubleshooting 15 5 1 S...

Page 3: ... turn the gas control knob Neverusetools Iftheknobwillnotpushinorturnbyhand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which...

Page 4: ... plumber or your local plumbing authority for more information DANGER HOT BURN To prevent burns Use the lowest operating temperature setting necessary to provide comfortably hot water If your household has children or elderly or disabled residents consider using a lower temperature setting Read all the instructions in this manual carefully before changing the temperature setting Feel the water bef...

Page 5: ...untry will void the manufacturer s warranty Ɣ Should overheating occur or the gas supply fail to shut off turn off the manual gas valve to the appliance Ɣ Do not use this appliance if any part has been under water Immediately call a qualifed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING Ɣ Shut off th...

Page 6: ...Condensate Drain Connection 2 1 Description of the Water Heater The NPE series water heater is available in 7 models NPE 150S NPE 180A NPE 180S NPE 210A NPE 210S NPE 240A and NPE 240S The main features are as follows Ɣ Potable domestic hot water combination space heating and commercial applications Ɣ Maximum temperature 182 F 83 C Ɣ Dual stainless steel Heat Exchangers with stainless steel piping ...

Page 7: ... Error g Master Unit A code will appear on the display Cascade operation b Hot Water Recirculation h Display Recirculation Mode c Diagnostics button i Up button For installers only Increases the temperature d Information button j Down button Shows basic information Decreases the temperature e Reset button k Power button Resets the water heater When an error occurs Turns the water heater on or off ...

Page 8: ...stops flashing the temperature setting is stored Note The water heater will retain your settings during a power outage You can adjust the temperature by the below 10 degree increments depending on the temperature range Temperature range Adjusting the water temperature 98 F 120 F Fahrenheit mode 36 C 50 C Celsius mode 1 F or 0 5 C increments 120 F 140 F Fahrenheit mode 50 C 60 C Celsius mode Press ...

Page 9: ...own button simultaneously for 10 seconds HIGH appears on the display Ɣ To exit Commercial Mode Press the up and down button simultaneously for 10 seconds LoW appears on the display Note Ɣ To adjust the temperature press the up button for 5 seconds to adjust in 10 F 5 C increments Ɣ Commercial Warranty Applies when this mode is used Refer to the Warranty for more details 3 3 Viewing Basic Informati...

Page 10: ...to drain the water heater before performing maintenance tasks such as cleaning the inlet water filter or to prevent the water heater from freezing when it will not be used for an extended period Refer to the 2 2 Parts of the Water Heater on page 6 for details about part locations To drain the water heater 1 Place a bucket under the water heater to collect the residual water inside the water heater...

Page 11: ... or larger Ɣ Cleaning solution diluted with water Ɣ 3 hoses Ɣ A water circulation pump To flush the Heat Exchanger A A B B C C D D Navien Easy valve Kit Cold Water Line Hot Water Line Circulation Pump Flushing Kit 6 Remove the recirculation inlet filter from the bottom of the water heater A model only Recirculation Inlet Filter A model only Pump Drain Plug A model only Cold Water Inlet Filter 7 Op...

Page 12: ...rever the water heater drains b Close the B valve and open the D valve Do not open the C valve yet c Allow water to flow through the water heater for 5 minutes d Close the A valve and open the C valve 11 Disconnect all tubes 12 Remove the cold water inlet filter from the water heater and clean out any residue 13 Reinsert the filter and ensure the filter cap is securely tightened 14 Reconnect the p...

Page 13: ...ton on the front panel to turn on the water heater 4 5 Cleaning the Air Intake Filter If the air intake filter becomes clogged by dust or lint the water heater will cease to operate and Error Code 110 will appear on the front panel display To properly maintain the water heater you should clean the air intake filter every 3 4 months To clean the air intake filter 1 Press the Power button on the fro...

Page 14: ...trongly recommend the use of a direct vent exhaust and intake system Your installer should ensure that the exhaust vent pipe and the air intake pipe are both connected directly from the collars on the top of the water heater to the outdoors This type of vent system minimizes air movement within the water heater Ɣ This water heater has an optional recirculation mode that is used for freeze protecti...

Page 15: ... Clean the cold water inlet filter See 4 4 Cleaning the Inlet Water Filter and Recirculation Inlet Filter on page 12 Ɣ Open the hot water faucet completely Ɣ If an error code is displayed refer to 5 2 Understanding Error Codes on page 16 It takes too long for hot water to reach the fixtures Are you using the external recirculation mode Have a contractor install a recirculation return line from the...

Page 16: ...ntact Technical Support at 1 800 519 8794 E421 Cold water inlet1 thermistor open or short circuit Contact Technical Support at 1 800 519 8794 E432 Cold water inlet2 thermistor open or short circuit Contact Technical Support at 1 800 519 8794 E434 Abnormal operation water adjustment valve Contact Technical Support at 1 800 519 8794 E438 Abnormal operation circulation pump Ɣ External Ensure that all...

Page 17: ... part s Navien at its sole descretion may replace the product with a new or refurbished product of comparable quality and design The replacement component part s will be warranted only for the unexpired portion of the original component part s Applicable Warranty Period Payment for labor in completing the warranty service is subject to Navien s prior written approval and shall be subject to Navien...

Page 18: ...any location outside the United States and Canada Ɣ Removal or alteration of the rating plate OtherTerms This Limited Warranty is subject further to the terms and conditions set forth herein and as may be further specified in the Terms and Conditions page located on Navien s website at www navien com WITH THE EXCEPTION OF THIS LIMITED WARRANTY NAVIEN DISCLAIMS ANY OBLIGATION OR LIABILITY WITH RESP...

Page 19: ......

Page 20: ...Contact a licensed professional for ected system for example a plumber or electrician When you contact Technical Support please have the following information at hand Model number Serial number Date purchased Installation location and type Error code if any appears on the front panel display Navien Inc 800 519 8794 www Navien com 20 Goodyear Irvine CA 92618 Operation Manual NPE Condensing Water He...

Reviews: