Appendixes
17. Once the CO
2
or offset values have been
confirmed, apply the included conversion
stickers to show that the appliance has been
converted to Propane Gas or High Altitude.
Place these labels adjacent to the rating plate as
Min. 3.40 mm to Max. 3.50 mm
Min. 8.0 to Max. 13.5 in WC
Conversion Kit No.:
NAC-L055/080
NHB-055H : Min. -0.02 in WC to Max. -0.11 in WC
NHB-080H : Min. -0.02 in WC to Max. -0.17 in WC
NHB-055H : Max. 55,000 - Min. 8,000 BTUh
NHB-080H : Max. 80,000 - Min. 8,000 BTUh
Min. 3.65 mm to Max. 4.30 mm
Conversion Kit No.:
NAC-L110
Min. 8.0 to Max. 13.5 in WC
Min. -0.02 in WC to Max. -0.26 in WC
Max. 110,000 - Min. 10,000 BTUh
Min. 3.65 mm to Max. 5.05 mm
Conversion Kit No.:
NAC-L150
Min. 8.0 to Max. 13.5 in WC
Min. -0.02 in WC to Max. -0.40 in WC
Max. 150,000 - Min. 10,000 BTUh
Min. 4.60 mm to Max. 5.50 mm
Min. -0.02 in WC
Max. 110,000 - Min. 10,000 BTUh
Min. 3.5 to Max. 10.5 in WC
Conversion Kit No.:
NAC-NH110
Min. 4.70 mm to Max. 6.60 mm
Min. -0.02 in WC
Max. 150,000 - Min. 10,000 BTUh
Min. 3.5 to Max. 10.5 in WC
Conversion Kit No.:
NAC-NH150
NHB-055H : Max. 55,000 - Min. 8,000 BTUh
NHB-080H : Max. 80,000 - Min. 8,000 BTUh
Min. 4.30 mm to Max. 4.40 mm
NHB-055H : Min. -0.02 in WC
NHB-080H : Min. -0.02 in WC
Min. 3.5 to Max. 10.5 in WC
Conversion Kit No.:
NAC-NH055/080
Figure 11. Proper Placement of
Gas Conversion Labels
Note
The gas conversion rating plate
varies depending on the model.
Check the conversion kit number