16 ErP Information
Product Fiche (EU regulation No 811/2013)
KD Navien
Unit
NCB700-24L
NCB700-28L
NCB700-34L
NCB700-40L
Central heating : temperature application
Medium
Medium
Medium
Medium
Water heating : the declared load profile
XL
XL
XL
XL
Seasonal central heating energy efficiency
class
A
A
A
A
Water heating energy efficiency class
A
A
A
A
Rated heat output
kW
20
23
28
33
Central heating : annual energy consumption
GJ
37
43
52
57
Water heating : annual electricity consumption
kWh
66
65
45
46
Water heating : annual fuel consumption
GJ
17
17
17
17
Seasonal central heating energy efficiency
%
92
93
93
93
Water heating energy efficiency
%
84
84
85
85
Sound power level
dB
50
52
54
52
Specific precautions
Read the user’s information and installation manual
before the application is assembled, installed or maintained.
ErP Information