background image

|  11 

Installation  |  

Broadband 3G/4G™ Radar Installation Guide

  Connect interconnection cable to the scanner

The scanner interconnection cable connects the scanner to the RI10 interface box  (or Lowrance 
HDS via and ethernet adapter cable - 3G U.S only). The cable connects to the scanner using a 
14 pin connector.

• 

Protect the connectors when pulling cable through the boat and avoid putting strain on 
to the connectors

• 

The interconnection cable is 9 mm in diameter. A 14 mm hole will be required in order 
for the RJ45 connector to pass through (Interface box end) or 24 mm for the scanner end 
connector

• 

Run the interconnection cable between the scanner and the location of the radar inter-
face box

• 

Insert cable connector on to the male 14 pin plug on the scanner

• 

Take care to align the connector correctly to avoid bending the pins. Secure the locking 
collar by rotating clockwise until it clicks

• 

Feed and secure the cable into the cable retention channel

Scanner Interconnection cable pin out 

Scanner connector

Cable connector

Diameter = 23 mm

Pin-out Wire color

RJ45

1

Black

Tinned wire

2

Red

Tinned wire

3

Yellow

Tinned wire

4

Drain

Tinned wire

5

N/A

N/A

6

Blue

RJ45 Pin 4

7

White / Blue

RJ45 Pin 5

8

White / Brown

RJ45 Pin 7

9

Brown

RJ45 Pin 8

10

White / Green

RJ45 Pin 3

11

N/A

N/A

12

White / Orange

RJ45 Pin 1

13

Green

RJ45 Pin 6

14

Orange

RJ45 Pin 2

 

RADAR_3G_4G_IG_988-10113-003_EN_P.indd   11

2/11/2011   1:59:44 p.m.

Summary of Contents for Broadband 4G

Page 1: ...ENGLISH Broadband3G Radar Broadband4G Radar Installation Guide www bandg com www simrad yachting com www lowrance com...

Page 2: ......

Page 3: ...tside USA or with MARPA chart overlay 15 Simrad NSS 16 B G Zeus 16 Simrad NSO NSE and NSS 17 RI10 Connections 17 Adding MARPA and or Chart Overlay 18 Connect power 19 Setup and Configuration 19 Enteri...

Page 4: ...cations However there is no guarantee that interference will not occur in a particular installation This device must accept any interference received including interference that may cause undesired op...

Page 5: ...ODUCT IN A WAY THAT MAY CAUSE ACCIDENTS DAMAGE OR THAT MAY VIOLATE THE LAW GoverningLanguage Thisstatement anyinstructionmanuals userguidesandotherinformation relating to the product Documentation may...

Page 6: ...ts No expensive magnetron replacement is ever required Incredibly approachable practically imperceptible transmit emissions are extremely safe allowing you to mount it anywhere Less than 1 5th the tra...

Page 7: ...of FMCW radar are Safety low energy emissions 1 5th of a mobile phone safe operation in anchorages and marinas instant power up No warm up required Short range performance broadband radar can see wit...

Page 8: ...ce 3G USA model and an interconnection cable The scanner is housed in a dome of similar size to most 2 kW radars on the market The RI10 interface box is used to connect displays power and heading info...

Page 9: ...S DON T install the scanner too high up eg at the top of a mast which may cause degradation of the radar picture over short ranges DON T install the scanner close to lamps or exhaust outlets The heat...

Page 10: ...hat the verti cal radar beam extends to 25 either side of horizontal With 50 of the power projecting in a beam 12 5 off horizontal If the radar beams cannot clear the roof line this will decrease per...

Page 11: ...etermine scanner height in relation to a vessels hard top overall width 0 85 m 1 0 m 1 2 m 1 4 m 1 6 m 1 8 m 2 0 m 2 4 m 2 6 m 2 8 m 3 0 m 2 2 m Direct Mount 70 mm 115 mm 163 mm 210 mm 255 mm 303 mm 3...

Page 12: ...hey are marine grade stainless steel and allow for minimum of 8 mm 0 3 and maximum of 18 mm 0 7 of thread contact 1 Use a 9 5 mm 3 8 drill bit to drill the four holes where shown on the mounting templ...

Page 13: ...scanner end connector Run the interconnection cable between the scanner and the location of the radar inter face box Insert cable connector on to the male 14 pin plug on the scanner Take care to alig...

Page 14: ...re D to the radar interface box using the four supplied M3x12 black s s screws H 5 Slide E along the cable G and press into the cable gland housing D A Radar interface box B Radar data connector RJ45...

Page 15: ...box Install the radar interface box where applicable in a dry location away from spray rain drips and condensation The radar interface box must be located where it can be easily connected to the ship...

Page 16: ...switch or using a free Ethernet port on a LSS 1 Structure Scan module if applicable Note Make sure this connection is made in a dry environment and is secured properly 3 Broadband 3G Radar 4 Interconn...

Page 17: ...dar 3 Interconnection cable Lowrance 10 m 33 ft Simrad 20 m 65 5 ft 4 RI10 Radar interface box 5 Ethernet cable 1 8 m 6 ft The RI10 can connect either directly to a Multifunction display or via an Eth...

Page 18: ...a 20 m 65 ft Optional 10 m 33 ft and 30 m 98 ft 4 RI10 Radar interface box 5 Ethernet cable 1 8 m 6 ft The RI10 can be connected directly to the NETWORK port of the display processor box or via a Net...

Page 19: ...ce box and the scanner connects directly to the display or Ethernet switch If chart overlay or MARPA are required for Lowrance HDS USA then an RI10 Interface box and heading sensor are required Adding...

Page 20: ...is turned on The display must be set to Master under Power Control When the display is off the radar will draw minimal power 1mA Before connecting power to the system make sure the scanner has been i...

Page 21: ...adar Status Software Version Check to make sure you have the latest software Check website for the latest version Serial Number Take a minute to write down the serial number of the radar MARPA Status...

Page 22: ...t returns can occur adjacent to strong target returns such as large ships or container ports This occurs because not all of the transmitted radar energy can be focused into a single beam by the radar...

Page 23: ...play At time of installation radar source selection needs to be performed as described below 1 Power up the system including both radars 2 On any display the first radar ever detected by the display w...

Page 24: ...With a Simrad NSE display connected to a Broadband 4G radar it s possible to run the radar in dual range mode This allows two radar panels to be veiwed simultaneously operating at different ranges bu...

Page 25: ...Avoid using abrasive cleaning products Do not use solvents such as gasoline acetone M E K etc as this will damage the dome surface After years of use the drive belt may have to be replaced The transmi...

Page 26: ...ension Drawings Scanner 280 mm 11 02 489 6 mm 19 28 488 6 mm 19 24 232 5 mm 9 15 114 6 mm 4 51 128 3 mm 5 05 128 3 mm 5 05 233 0 mm 9 17 141 5 mm 5 57 C A D B FRONT Key Description A Cable entry area...

Page 27: ...25 Dimension Drawings Broadband 3G 4G Radar Installation Guide Radar interface box 171 mm 6 76 92 mm 3 63 154 mm 6 06 25 MM 1...

Page 28: ...ce warm up time No Magnetron all solid state Instant On Plane of polarization Horizontal Polarization Transmitter peak power output 165 mW nominal at source Main bang dead zone tuning None not a pulse...

Page 29: ...state Instant On Plane of polarization Horizontal Polarization Transmitter peak power output 165 mW nominal at antenna port Main bang dead zone tuning None not a pulse radar Sea and rain clutter 3 5...

Page 30: ...female Supplied with Lowrance USA SKU 2 m 6 5 ft 000 00127 28 Ethernet cable 0 6 m 2 ft 000 0127 51 Ethernet cable 1 8 m 6 ft 000 0127 29 Ethernet cable 4 5 m 15 ft 000 0127 30 Ethernet cable 7 7 m 2...

Page 31: ...29 RF exposure compliance certificate Broadband 3G 4G Radar Installation Guide RF exposure compliance certificate 11...

Page 32: ...30 RF exposure compliance certificate Broadband 3G 4G Radar Installation Guide...

Page 33: ...31 RF exposure compliance certificate Broadband 3G 4G Radar Installation Guide...

Page 34: ...988 10113 003 www bandg com www simrad yachting com www lowrance com...

Reviews: