background image

NA

Y

AC 

Contents 

1. Use Information ........................................................................................................ ... ... ...  1 

2.  Attention ............................................................................................................................  1 

3. Description  ..................................................................................................................... 3 

3.1 Principle of Operation .................................................................................................... 3 

3.2 Principle of Gas Ballast .............................................................................. ... ... ... ... ... ...  3 

4. Technical Parameters  ...................................................... ................................................ 4 

5. Transport and Storage .......................................................................................................  5 

6. Installation and Connection ................................................................................................. 5 

6.1 Installation Dimensions .................................................................................................. 5 

6.2 Connection to System  .................................................................................. ... ... ... ... ...  6 

6.3 Power Supply and Motor Rotation Direction  ..................................................................... 7 

7. Initial Start and Operation .................................................................................................... 7 

7.1 Start-up ...................................................................................................................... 7 

7.2 Operation  ................................................................................................................. 7 

8. Inspection and Maintenance  .............................................................................................. 8 

8.1 Inspection  ................................................................................................................ 9 

8.2 Maintenance ..............................................................................................................  9 

9. Troubleshooting ............................................................................................................. 10 

10. Warranty ........................................................................................................................ 11 

11. Accessories  .................................................................................................................  11 

11.1 NRD Exploded View  ........................................................................................................  12 

11.2 NRD Spare Parts List. .................................................................................................. ...  1 3 

1. Use information

Dear distinguished customer, 

Thanks for choosing NAVAC vacuum pump of high reliability  (Hereinafter referred to as "the pump"). 

Please check carefully whether the product received is the same as you ordered and the accessories, spare parts & operating 

manual are attached as well. Please also check if there's any damage occurred during transportation. If needed, contact the local 
distributor or our sales team. 

In order to maintain a stable performance level of the pump, read this operating manual carefully to fully understand the safety 

instructions, technical data as well as operating procedures before installation, operation, repair and maintenance of the pump. 

• 

Caution 

To reduce the risk of electric shock, do not expose to rain. Store indoors. 

!

Warning

Failure to observe the terms could result in serious personal injury. 

• 

Notice 

Failure to observe the terms could result in damage to the pump. 

• 

This warning label indicates risk of electrical shock. Disconnect the pump from the power supply before beginning with 
connections,repair and maintenance. Make sure the cover of junction box is properly installed before running. 

This warning label indicates high temperature hazard. Do not touch the pump when the pump is in operation. 

The product should be placed steadily on the floor without any incline. 

Notice 

Put the plug of power supply cord into the outlet and fasten the metal clasp to prevent falling off when the product is prepared 

for normal use. If it has finished its job , please get the plug off and keep the pump housing dustproof by covering a clean film 
plastic bag on it. 

• 

Notice 

Read the operating manual  carefully and follow the operating procedures. We reserve the right to modify the design and 

technical data of the pump without notice which may have discrepancies in the manual. Add vacuum oil as requested before 

starting the new pump. 

2. Attention

In order to ensure the personal safety, read the operating manual carefully before installation, operation, repair and maintenance. 

!

Warning

According to the technical guidelines and wiring regulations for electrical equipment, the power  supply  must  match with 
the information shown on the pump nameplate and the electrical connections must be performed by a skilled electrician. 

!

Warning

To prevent electrical hazards and sudden start-up hazard which may result in personal  injury,  disconnect the power supply 
before checking or repairing the pump. 

Summary of Contents for NRD Series

Page 1: ...C NRD Series User Manual Dual Stage Oil sealed Rotary Vane Vacuum Pump NRD16 16T l E _ 5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot...

Page 2: ...ury Notice Failure to observe the terms could result in damage to the pump This warning label indicates risk of electrical shock Disconnect the pump from the power supply before beginning with connect...

Page 3: ...tive gas within the scope of low vacuum and a small amount of non condensable gas The pump is specially suitable for coating refrigeration freeze drying sterilization instruments analysis leak detecti...

Page 4: ...D4 Without gas ballast With gas ballast Pressure Pa Fig 3 5 Transport and Storage Warning Do not move the pump unless it s switched off and the power supply is disconnected Warning Make sure that the...

Page 5: ...ich can shut off the entire product In the event that the thermal limiter operates nothing is need to do but waiting for the motor to restart automatically if it has been cooled to the temperature whi...

Page 6: ...n the first time and follow all appropriate safety procedures If the potential hazard still exists the pump must be decontaminated before any maintenance 8 1 Routine inspection Content Operation Inter...

Page 7: ...ithin rated voltage s tolerance of 10 2 Repair the pump 3 Add the oil to the level as requested 4 Disassembly and replace the parts 1 Improve ventilation environment 2 Change the fan 3 Add cold trap a...

Page 8: ...01 Gas ballast 15 0 ring FKM 300310079 Support 16 Gasket Paper 320210101 Front chanter 17 Seal FKM 300280602 Front chanter 18 Spring SUS 320110104 Front rear rotor 5 NRD16 320100101 Front rotor 2 19 V...