9.2.4
1. Turn on charging machine and go to main menu.
2. Place batteries in probes.
3. Press power button 1s to turn on.
4. Auto sync between charging machine and probes. After successful sync, probe battery signals
show on.
9.2.4 Process for synchronizing
1. Below re-sync operation for sync failure or new temperature probe.
2. When "HT", "LT" signals and probe yellow flash, it means not sync.
3. Go to "Main Menu", "Initial Setup", "High Temp Sensor Bluetooth/ Low Temp Sensor Bluetooth",
"Sync". Press "ENTER" to operate.
4_ If sync succeed within 1 minute, the bluetooth signal is on. If not, the signal is grey.
9.2.6
Item
Status
Red flash
Battery is close out.
Auto shut-off
Battey is out soon.
Yellow flash
Not sync.
When scale or temperature probes can not measure correctly due to personal improper drop or
impact, return them to NAVAC dealer to repair or calibrate.
13