NAVAC NRC62D User Manual Download Page 10

Empowering you to work smarter 

NAVAC 

TROUBLESHOOTING 

PROBLEM 

CAUSE 

REMEDY 

1. Motor or power supply fails 

Check and repair 

2.  Power  voltage  is too low 

Check power voltage 

Difficult start-up 

3. Extension power cable is too long 

Shorten the length of power cord to 

eliminate voltage drop 

4.  Foreign substance falls into the vacuum 

Check and dear it 

pump 

1. Vacuum pump oil seal is damaged 

Replace the oil seal 

Oil leaking 

2. Oil tank connecting tube is loose or 

damaged 

Tighten the screw or replace the O ring 

Oil discharge from 

1. Too much oil in pump 

Drain oil to the oil level line 

filVexhaust cap 

1.  Insufficient  oil in the vacuum pump 

Fill oil to the centerline of oil mark 

2. Engine oil in the vacuum pump is 

emulsified, or dirty 

Replace with new oil 

3. Oil inlet port of vacuum pump is blocked 

Clean oil inlet port and filter screen 

Leak alarm in 

or oil supply to the pump is insufficient 

vacuum mode 

4. The copper connection hose leaks 

Check the connection hose 

5. Components on the pump worn out due 

Check and repair the pump or replace it 

to long hours of use 

with a new one 

6. Manifold connection is loose 

Tighten the connector 

1. The wireless electronic scale is too far 

Have the electronic scale close to the 

from the Charging System 

charging system 

2. The weight of the refrigerant cylinder is 

beyond the range of the electronic scale 

Select a proper refrigerant cylinder 

Electronic scale 

Re-sync the scale to the charging 

alarm 

3. Something is wrong with wireless sync 

system following instructions 

4. There is no refrigerant cylinder on the 

Put the refrigerant cylinder on the scale 

scale while charging 

Alarm because of 

1. Not enough refrigerant left in cylinder, or 

Replace the refrigerant cylinder, or 

insufficient pressure 

cylinder has been in very cold ambient 

warm ff very cold 

conditions 

Temperature probe 

1. probe is too far from charging machine 

Place it closer 

alarm 

2. not sync 

Re-sync 

17 

Empowering you to work smarter 

NAVAC 

18 

Summary of Contents for NRC62D

Page 1: ...5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...ation and charging machine designed for use only by trained HVACR professionals and can be damaged or dangerous if operated incorrectly 2 For your safety and correct operation please read the operatio...

Page 3: ...ant has been evacuated Precautions at operation and use of refrigerant Under the normalcircumstances refrigerant is apressurizedliquid For ease of use and transportation it is stored in a certified cy...

Page 4: ...splay area A2 Current procedure Status and Warning E1 High temperature probe error E2 Low temperature probe error E3 Vacuum sensor error If these errors occur contact our dealer or technical support F...

Page 5: ...sure connection on the charging machine and the other end with the suction line on the equipment Connect one end of the red hose with HP high pressure connection on the charging machine and the other...

Page 6: ...vel will degrade performance of the pump while too high oil level will cause a large quantity of oil mist to discharge fromthe oilfill port 09 Empowering you to work smarter N AV AC Replace vacuum pum...

Page 7: ...bluetooth button 11 Empowering you to work smarter N AYf AC 9 1 3 Process for synchronizing wireless communication 1 Make sure the scale is not weight loaded Turn on the charging machine and scale If...

Page 8: ...hen HT LT signals and probe yellow flash it meansnot sync 3 Go to Main Menu Initial Setup High Temp Sensor Bluetooth Low Temp Sensor Bluetooth Sync Press ENTER tooperate 4_ If sync succeed within 1 mi...

Page 9: ...Return ValveAssy 1 17 CRP 17 Dustproof Screen 1 18 CRP 18 Vacuum Pump 1 19 CRP 19 Rubber Feet I 4 20 CRP 20 Rubber Feet II 3 21 CRP 21 Base PlateAssy 1 22 CRP 22 Rubber Buffer 5 23 CRP 23 Valve Body...

Page 10: ...is insufficient vacuum mode 4 The copper connection hose leaks Check the connection hose 5 Components on the pump worn out due Check and repair the pump or replace it to long hours of use with a new...