background image

Document NO.  M-7001A-EM-English 

PAGE 

Page 8 of 18 

Engineer Manual-Trouble Shooting 

VERSION 

 

2.15.

 

Error message『Err6』:Incline motor can not reach set position over 42 seconds 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Show Err6 

Reset power 

OFF 

ON 

Does incline motor moving? 

Yes 

No 

Incline motor jammed, to eliminate jam problem then check

 

the inverter shall be the new version (refer to 1.3.) 
and console firmware version great than V1.05, if not, 
replace or update it.

 

Is it move about 1~2 then stop

 

Yes 

No 

Press Start then set incline 

to 15. 

System operating normal but please check 

the inverter 

shall be the new version and console firmware version 
great than V1.05, if not, replace or update it.

 

Replace incline motor and check 

the inverter 

shall be the new version (refer to 1.3.) and 
console firmware version great than V1.05, 
if not, replace or update it.

 

Summary of Contents for M-7001 A

Page 1: ...Document NO M 7001A EM English PAGE Page 1 of 18 Engineer Manual Trouble Shooting VERSION C ENGINEER MANUAL FOR AFTER SALE SERVICE PRODUCT TREADMILL MODEL M 7001 SERIES A TYPE ...

Page 2: ...or message OL Page 7 2 10 Error message OL1 Page 7 2 11 Error message ntcF Page 7 2 12 Error message LF Page 7 2 13 Error message dbuP Page 7 2 14 Error message Err7 Page 7 2 15 Error message Err6 Page 8 2 16 Error message ESP Page 9 2 17 Error message UArt Page 10 2 18 Error message Err1 Page 11 3 Other Information 3 1 Console no power No any display Page 12 3 2 Distance window shown Err only Pag...

Page 3: ...Document NO M 7001A EM English PAGE Page 3 of 18 Engineer Manual Trouble Shooting VERSION C 1 Information For Components System 1 1 System wiring diagram ...

Page 4: ...232 P5 12V P2 RS485 DX RXD RS232 P6 G12 GND P3 EXG P7 SAFETY KEY P4 WK_UP Wireless receiver Jk8 P1 sensor input P2 VCC P3 GND SAFE KEY Jk4 P1 Driver EN P2 VDD STOP key Jk14 P1 KeyBoard S5 P2 KeyBoard D2 FAN Jk1 P1 PWM 0 12V P2 VDD Hand Pulse Jk7 P1 Left reference electrode P3 Right signal electrode P2 Left signal electrode P4 Right reference electrode Quick shift SPEED J5 P1 SPD P2 COM P3 SPD Quic...

Page 5: ...terval 2 7 X 8 D3 Valley Random 3 8 X 9 D4 Fat Burn Fitness Test 4 9 X 10 D5 Ramp H R C 5 0 Enter MEMBRANE KEYBOARD R Right 8P 1 S6 2 S7 3 S8 4 S9 5 D6 Inc 8 Spd 4 Cool Down Inc Up 6 D7 Inc 6 Spd 6 Fan Inc Down 7 D8 Inc 4 Spd 8 Stop Spd 8 D9 Inc 2 Spd 10 Start Spd 1 3 Inverter Please replace to new version inverter if it is a old version one Old version inverter New version inverter With resistors...

Page 6: ...lt or deck if always happen while running 2 3 Error message OE The operation voltage too high maybe happen at high incline level and heavy load exercising contact manufacture for solution 2 4 Error message PrEr The inverter Flash memory problem replace the inverter 2 5 Error message EEr The inverter EEPROM problem replace the inverter 2 6 Error message LE The voltage is too low when in idle or set...

Page 7: ...2 10 Error message OL1 The motor current overload over 150 have to replace the running belt or deck 2 11 Error message ntcF The thermo sensor abnormal replace inverter 2 12 Error message LF The motor wires did not connect well 2 13 Error message dbuP The inverter dynamic brake system damaged replace inverter 2 14 Error message Err7 The incline motor position parameter over max or min limit check t...

Page 8: ...erter shall be the new version refer to 1 3 and console firmware version great than V1 05 if not replace or update it Is it move about 1 2 then stop Yes No Press Start then set incline to 15 System operating normal but please check the inverter shall be the new version and console firmware version great than V1 05 if not replace or update it Replace incline motor and check the inverter shall be th...

Page 9: ...RSION C 2 16 Error message ESP Inverter emergency protection Show ESP Open motor cover Dis connect ESP wire from inverter Short circuit the ESP terminal with a screw Metal Reset AC power and wait 5 seconds Is it still show ESP Yes Replace inverter No Replace console communication wire ...

Page 10: ...C 2 17 Error message UArt Communication time out console can not communication with inverter over 10 seconds Open motor cover Switch ON the power Does communication lamp where on the inverter flash before console show UArt Flash No Flash Replace inverter Replace console or communication wire ...

Page 11: ...on to the newest version great than V1 05 No Set incline to level 15 then set to level 0 Does the incline work abnormal and stop then show Err1 Yes No System operating normal but please check the inverter shall be the new version and console firmware version great than V1 05 if not replace or update it The incline motor jammed or input power too low the input power shall over 90V 110V system 200V ...

Page 12: ...ow shown Err only no any error message show on time window To check the motor wires connection or replace inverter 3 3 Console work normally but motor can not move To check the motor wires connection same as upon or replace inverter Does lamp lights up on inverter Console no power Open motor cover Yes No Replace inverter Replace console Check motor wires connection ...

Page 13: ...onds to enter engineer mode Reset power OFF ON Press Enter till dot matrix show IO Press incline up to drive incline motor Does incline motor move Yes No Incline motor jammed have to eliminate and try again Is parameter can be increase up over 700 when motor move up Press incline up again to stop the incline motor while parameter over 700 Yes System operating normal No Replace incline motor No Rep...

Page 14: ...4 1 1 4 Keys test mode dot matrix show KEY each key has their own code when press a key the code show as below press Enter to next test mode 4 1 1 5 Test mode Press Start can drive motor press speed keys to change speed press incline keys to drive incline motor press Enter back to 4 1 1 1 retest press and hold RESET CLEAR then press Quick Start 3 seconds to exit Key Code Key Code Key Code Key Code...

Page 15: ...n show METRIC METRIC METRIC METRIC press or change to ENGLISH ENGLISH ENGLISH ENGLISH press ENTER to next setting 4 2 1 4 FAN SETTING Dot matrix show FAN SETTING one time then show ON ON ON ON press or change to OFF OFF OFF OFF press ENTER to next setting 4 2 1 5 MIN SPEED Dot matrix show SET MIN SPEED THEN PRESS ENTER SPEED window show value press or to set value press ENTER to next setting 4 2 1...

Page 16: ... 5 Inverter Information and External Control 5 1 External control Key Pad usage 5 1 1 External control Key Pad appearance KP 208 and connection 5 1 2 Monitor mode and operation Output frequency Frequency setting Output voltage PN Voltage Output current void void void Incline setting void void ...

Page 17: ...5 1 3 To control inverter by External control Key Pad 5 1 3 1 Start Stop Fast Slow Start Stop Fast Slow Press PROG change to function setting at any display mode press to show F_001 Press FUN DATA enter the F_001 setting default value is 0 Press change value to 1 Press FUN DATA to save and exit ...

Page 18: ...ocument NO M 7001A EM English PAGE Page 18 of 18 Engineer Manual Trouble Shooting VERSION C 5 1 3 2 Incline control Parameter setting Incline parameter Incline UP Incline Down Monitor mode Monitor mode 9 ...

Reviews: