12
a. ENTER MFG TEST – This option is intended for use on the manufacturing production line only. It is a chained
series of tests similar to the tests listed below, but optimized to be run on the production line. This chained test
should not be used anywhere but on the production line.
b. DEBUG TERMINAL – Not used.
c. MOVE LIFT – (E618 elliptical only) Used to adjust a new lift motor. The Console displays “UP MX DN MN RT
CAL”: Up arrow will move the lift motor to the maximum position; Down arrow will move the lift motor to the
minimum position; Right arrow will perform a lift motor calibration by moving the lift motor to its minimum and
maximum position. Note: Lift motor calibration is no longer required, so calibration is not needed.
d. RESET MFG NVM – Resets MFG NVM (non volatile memory). Must be run before lift motor calibration if a valid
lift table exists in NVM (lift motor has been calibrated before).
e. RUN BEEP TEST – Sounds each system beep / tone / sequence in order. Press any key to exit
f. RUN BUTTON TEST – The Console display shows the function of each button as buttons are pressed. If the
display shows an incorrect function, the overlay on the Console may be incorrect for that model. If the display
does not show a function, the firmware version may be incorrect. No beeps are sounded during this test.
To exit the test, push and hold one of the long key sequences (i.e. long Pause / End + Right or long Pause / End +
Down).
g. RUN LED TEST – Drives LEDs to the following states:
1.
All LEDs On 1 second
2.
All LEDs Off 1 second
3.
Sequence Segments 1 at a time – on 1 second, off 1 second
Press any key to exit test
h. RUN LCD TEST – Drives 3x5 and 1x5 LCD displays with the following patterns:
1.
All segments on
2.
All segments off
3.
Set individual segments one at a time until all segments are illuminated.
Press any key to exit.
i. RESET CONSOLE – Resets the data from user inputs. The Console setup, user records and workout records will
be reset to defaults. This option does not reset MFG NVM (non volatile memory).
11. The Console display shows the Software Version prompt.
12. For the next prompt, push the OK button.
13 . The Console will display the Power-Up Mode screen.