14
1.
Install the CR2032 battery provided into
the battery compartment on the circuit
board inside the front part of the
housing.
6.
Setting up the moisture alarm:
2.
Switch the alarm on. The LED light will
turn blue for five seconds indicating the
battery is normal. Then it goes into
flashing blue light standby mode.
3.
Test the alarm by contacting the two
wires near the bottom of the housing
with a damped cotton bud; the alarm
should start giving out a repeating
“beep” sound along with a flashing red
light. The “beep” sound and the light
should keep on going for 5 seconds
after the removal of the damped
cotton bud .