XR6/XR3 Pre-installation Manual
Control and monitoring
Issue 3.0 2009-07-15
Page 6-9
•
TB2-6 (-):
PDM INHB
terminal. Continuous active signal inhibits the PDM by causing a shut-
back. This also works when the remote/local status is set to local.
•
TB1-1 and TB1-2:
EXT INTLK
terminals. A short circuit between the pins for normal operat-
ing status, an open between these pins causes a shutback. This also works when the remote/
local status is set to local.
•
TB1-4 (-):
RF OFF
terminal. Same as pressing the
RF Off
button on the front panel. Provide
an active pulse to activate.
•
TB1-6 (-):
RF ON
terminal. Same as pressing the
RF On
button on the front panel. Tells the
system to provide RF power if possible. Provide an active pulse to activate.
•
TB1-8 (-):
RESET
terminal. Causes a system reset. Provide an active pulse to activate.
•
J3-23 (-):
IBOC Input Select A
input. Sets IBOC/Analog for Exciter A. Continuous active sig-
nal selects IBOC input, otherwise analog input is selected.
•
J3-25 (-):
IBOC Input Select B
input. Sets IBOC/Analog for Exciter B. Continuous active sig-
nal selects IBOC input, otherwise analog input is selected.
•
J2-10 (-):
Preset Scheduler (Auto/Man)
input. Enables or disables the Automatic Preset (for-
merly power level) changes. Provide an active pulse to toggle between Auto or Manual
modes.
The following inputs will only take effect when the Preset Scheduler Mode is set to Manual.
•
J2-12 (-):
Preset 1
input. Selects RF power preset 1 of 6. Provide an active pulse to activate.
•
J2-14 (-):
Preset 2
input. Selects RF power preset 2 of 6. Provide an active pulse to activate.
•
J2-16 (-):
Preset 3
input. Selects RF power preset 3 of 6. Provide an active pulse to activate.
•
J2-18 (-):
Preset 4
input. Selects RF power preset 4 of 6. Provide an active pulse to activate.
•
J2-20 (-):
Preset 5
input. Selects RF power preset 5 of 6. Provide an active pulse to activate.
•
J2-22 (-):
Preset 6
input. Selects RF power preset 5 of 6. Provide an active pulse to activate.
Note: A minimum one second interval between commands is required for the
following two exciter selection commands.
Summary of Contents for XR6
Page 2: ...blank...
Page 4: ...blank...
Page 8: ...XR6 XR3 Pre installation Manual Page viii Issue 3 0 2009 07 15...
Page 12: ...XR6 XR3 Pre installation Manual Page xii Issue 3 0 2009 07 15...
Page 20: ...XR6 XR3 Pre installation Manual Page xx Issue 3 0 2009 07 15...
Page 24: ...XR6 XR3 Pre installation Manual Description Page 1 4 Issue 3 0 2009 07 15...
Page 28: ...XR6 XR3 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 0 2009 07 15...
Page 34: ...XR6 XR3 Pre installation Manual Physical requirements Page 3 6 Issue 3 0 2009 07 15...
Page 38: ...XR6 XR3 Pre installation Manual Cooling requirements Page 4 4 Issue 3 0 2009 07 15...
Page 56: ...XR6 XR3 Pre installation Manual Control and monitoring Page 6 14 Issue 3 0 2009 07 15...
Page 62: ...XR6 XR3 Pre installation Manual RF output requirements Page 8 4 Issue 3 0 2009 07 15...
Page 66: ...XR6 XR3 Pre installation Manual Parts and tools Page 9 4 Issue 3 0 2009 07 15...
Page 88: ...XR6 XR3 Pre installation Manual Page IX 6 Issue 3 0 2009 07 15...
Page 89: ......