![Nautel XR6 Preinstallation Manual Download Page 39](http://html2.mh-extra.com/html/nautel/xr6/xr6_preinstallation-manual_3625959039.webp)
XR6/XR3 Pre-installation Manual
Electrical requirements
Issue 3.0 2009-07-15
Page 5-1
Section 5:
Electrical requirements
This section describes electrical power and electrical protection requirements associated with the
XR6/XR3 transmitter. This section includes the following topics:
•
•
Station reference ground - see page 5-4
Refer to the
Nautel Site Protection Manual
for information about requirements associated with lightning
protection.
Electrical power
The transmitter is preconfigured to operate from a 50/60 Hz, 3-phase (3-wire plus ground, Wye or
closed delta)or 1-phase (2-wire plus ground) ac power source. You select the number of phases and
specific voltage range when you order the transmitter.
Nominal voltage (minimum and maximum)
The primary winding of the main ac power transformer contains taps to accommodate voltages that
differ from the ideal voltage of the power source. These taps provide increments and are selected
during installation to provide the nominal voltage for the transmitter.
The high voltage transformer comes with the following standard taps:
CAUTION: Technical pre-commissioning activities described in this section
require technical decisions and the customization of electrical circuits. Do
not attempt to perform these activities unless you are a certified
electrician.
Table 5.1: Nominal Voltages
Ac Power
Source
Transformer
Standard Voltage Taps
3-phase
LV
198, 208, 218, 229, 239, 250
HV
342, 361, 380, 399, 418, 437
1-phase
-
200, 220, 240, 260
Summary of Contents for XR6
Page 2: ...blank...
Page 4: ...blank...
Page 8: ...XR6 XR3 Pre installation Manual Page viii Issue 3 0 2009 07 15...
Page 12: ...XR6 XR3 Pre installation Manual Page xii Issue 3 0 2009 07 15...
Page 20: ...XR6 XR3 Pre installation Manual Page xx Issue 3 0 2009 07 15...
Page 24: ...XR6 XR3 Pre installation Manual Description Page 1 4 Issue 3 0 2009 07 15...
Page 28: ...XR6 XR3 Pre installation Manual Pre installation tasks Page 2 4 Issue 3 0 2009 07 15...
Page 34: ...XR6 XR3 Pre installation Manual Physical requirements Page 3 6 Issue 3 0 2009 07 15...
Page 38: ...XR6 XR3 Pre installation Manual Cooling requirements Page 4 4 Issue 3 0 2009 07 15...
Page 56: ...XR6 XR3 Pre installation Manual Control and monitoring Page 6 14 Issue 3 0 2009 07 15...
Page 62: ...XR6 XR3 Pre installation Manual RF output requirements Page 8 4 Issue 3 0 2009 07 15...
Page 66: ...XR6 XR3 Pre installation Manual Parts and tools Page 9 4 Issue 3 0 2009 07 15...
Page 88: ...XR6 XR3 Pre installation Manual Page IX 6 Issue 3 0 2009 07 15...
Page 89: ......