12 000 WATT AM BROADCAST TRANSMITTER
XL12
Page 2-16
01 January 2002
#12
to
A23A1T1-Y1
#13
to
A23A1T1-Y2
#14
to
A23A1T1-Y3
(d)
Locate three grey, 20AWG wires (#329, #330
and #331 which originate at the DC power
supply PWB and route them to the vicinity of
the fuseholder (XF1) on the top of the
transformer. Connect:
#329
to
A1T1XF1-2
#330
to
A1T1XF1-4
#331
to
A1T1XF1-6
2.2.7 AC POWER CONNECTION:
Install the
circuit breaker enclosure (ac input switch) supplied
with the transmitter and the interconnecting electrical
wiring, between the AC power service entrance and
the transmitter as follows:
NOTE
The user must determine the entry point for the
AC power wiring and then open the appropriate
sized cable entry hole in the transmitter cabinet.
Pilot holes are located at both top, rear corners
to accommodate top entry. The installer must
drill or punch the appropriate sized cable entry
hole.
A double knockout is located at the bottom, rear,
left-hand corner (viewed from front) of the
cabinet to accommodate bottom entry. Access is
gained through a hole in the AC/DC power
supply chassis. If this option is selected, the
installer must knock-out the appropriate sized
cable entry hole.
If any other entry location is required, the
installer must ensure the wiring will not interfere
with transmitter assemblies and then drill/punch
the appropriate sized cable entry hole.
It is recommended the interconnecting electrical
wiring be installed in a metal conduit which is
rigidly attached at both ends.
2.2.7.1 Installation of Circuit Breaker
Enclosure :
Install the circuit breaker enclosure in
close proximity to the transmitter, noting it is a
dedicated interface between the AC power service
entrance and the transmitter. Refer to figure MD-29
for the circuit breaker enclosure's dimensional/
assembly information.
NOTE
The circuit breaker enclosure contains a number
of knockouts (top and bottom) to accommodate
different wiring configurations. The installer
must knock out the appropriate cable entry holes
where the electrical wiring enters/exits the
enclosure.
A sealed safety wire is installed thru holes in the
bolts which secure IEC125 key lock systems. It
provides a visual confirmation the lock has not
been tampered with. Removal or breaking the
seal of this safety wire will defeat its purpose and
may compromise the safety of maintainers.
2.2.7.2 Installation of AC Power Wiring
(Service Entrance to Enclosure):
Connect the
AC power wiring which will interconnect the service
entrance to the
LINE
side of the circuit breaker in the
circuit breaker enclosure. All wiring must be in
conformance with the local electrical codes.
NOTE
Do not install a neutral conductor unless the
local electrical code specifically requires it. If it
is necessary, connect it as dictated by the local
codes.
2.2.7.3 Installation of AC Power Wiring
(Enclosure to Transmitter):
Connect the AC
power wiring which will interconnect the
LOAD
side
of the circuit breaker (in the circuit breaker
enclosure) to main power contactor A23K2 and
A23TB1 (ground) (in the transmitter) as follows
(refer to figure MD-2 as an aid in locating A23K2
and A23TB1, noting they are accessed through the
rear door):
(a)
At the transmitter end, route AC power wiring
through the preselected and prepared cable
entry hole to the vicinity of contactor A23K2
and terminal board A23TB1. Cut each
conductor to length and install them as follows:
Line (
φ
) 1
-
A23K2-L1
Line (
φ
) 2
-
A23K2-L2
Line (
φ
) 3
-
A23K2-L3
Ground
-
A23TB1-2
NOTE
A23K2 terminals require a 5/32 inch or 4mm hex
head wrench.
Summary of Contents for XL12
Page 194: ...Figure SD 2 Electrical Schematic Exciter Stage Page SD 2 01 January 2002...
Page 195: ...Figure SD 3 Electrical Schematic RF Drive Stage Page SD 3 01 January 2002...
Page 196: ...Figure SD 4 Electrical Schematic RF Power Stage Page SD 4 01 January 2002...
Page 197: ...Figure SD 5 Electrical Schematic Control Monitor Functions Page SD 5 01 January 2002...
Page 198: ...Figure SD 6 Electrical Schematic AC DC Power Stage Page SD 6 01 January 2002...
Page 199: ...Figure SD 7 Electrical Schematic Remote Interface PWB NAPI25A Page SD 7 01 January 2002...
Page 200: ...Figure SD 8 Electrical Schematic Exciter Interface PWB NAPI22E Page SD 8 01 January 2002...
Page 201: ...Figure SD 9 Electrical Schematic RF Drive Tuning PWB NAPI60 Page SD 9 01 January 2002...
Page 202: ...Figure SD 10 Electrical Schematic Distribution PWB NAPI50B Page SD 10 01 January 2002...
Page 203: ...Figure SD 11 Electrical Schematic DC Power Supply PWB NAPS16C Page SD 11 01 January 2002...
Page 210: ...Figure MD 3 Assembly Detail NAC101 Control Monitor Panel Page MD 3 01 January 2002...
Page 212: ...Figure MD 5 Assembly Detail NAPI25A Remote Interface PWB Page MD 5 01 January 2002...
Page 213: ...Figure MD 6 Assembly Detail NAE73A Exciter Panel Page MD 6 01 January 2002...
Page 214: ...Figure MD 7 Assembly Detail NAPI22E Exciter Interface PWB Page MD 7 01 January 2002...
Page 215: ...Figure MD 8 Assembly Detail NAE83 RF Drive Panel Page MD 8 01 January 2002...
Page 216: ...Figure MD 9 Assembly Detail NAAA02 RF Drive Amplifier Page MD 9 01 January 2002...
Page 219: ...Figure MD 11 Assembly Detail NAPS10B Regulated Power Supply PWB Page MD 11 01 January 2002...
Page 220: ...Figure MD 12 Assembly Detail NAPI50B Distribution PWB Page MD 12 01 January 2002...
Page 221: ...Figure MD 13 Assembly Detail Fan Tray P N 183 8350 Page MD 13 01 January 2002...
Page 222: ...Figure MD 14 Assembly Detail NAF102 RF Output Filter Top View Page MD 14 01 January 2002...
Page 223: ...Figure MD 15 Assembly Detail NAF102 RF Output Filter Rear View Page MD 15 01 January 2002...
Page 224: ...Figure MD 16 Assembly Detail NAFP90 Forward Reflected Power Probe Page MD 16 01 January 2002...
Page 225: ...Figure MD 17 Assembly Detail NAX161 Static Drain Choke Page MD 17 01 January 2002...
Page 228: ...Figure MD 20 Assembly Detail NAPP02 RF Current Probe PWB Page MD 20 01 January 2002...
Page 229: ...Figure MD 21 Assembly Detail Capacitive Divider Assembly 176 8253 Page MD 21 01 January 2002...
Page 231: ...Figure MD 23 Assembly Detail NASR108 AC DC Power Supply Top View Page MD 23 01 January 2002...
Page 232: ...Figure MD 24 Assembly Detail NASR105 01 Power Transformer Assembly Page MD 24 01 January 2002...
Page 233: ...Figure MD 25 Assembly Detail 3 Rectifier UP28 Page MD 25 01 January 2002...
Page 234: ...Figure MD 26 Assembly Detail NAPS16C DC Power Supply PWB Page MD 26 01 January 2002...
Page 235: ...Figure MD 27 Assembly Detail NAPI48B DC Power Supply Monitor PWB Page MD 27 01 January 2002...