![Nautel XL12 Technical Instructions Download Page 33](http://html1.mh-extra.com/html/nautel/xl12/xl12_technical-instructions_3617474033.webp)
12 000 WATT AM BROADCAST TRANSMITTER
XL12
Page 2-9
01 January 2002
2.1.11.9 B+ Power Supply Fault Alarm:
An
alarm output that indicates the RF output has been
inhibited, because the output of the B+ DC power
supply is not within 10% of its optimum voltage (over
or under) is available on TB3-5 (
B+ P/S FAIL
). A
negative logic output (current-sink-to-ground) will be
present for an alarm condition.
2.1.11.10 AC Fail Alarm:
An alarm output that
indicates the RF output has been inhibited; because
the voltage from the AC power source is more than
ten percent below the ideal voltage for the power
transformer's selected primary winding taps, or a loss
of phase has occurred; is available on TB3-6 (
AC
FAIL
). A negative logic output (current-sink-to-
ground) will be present for an alarm condition.
2.1.11.11 Power Supply Over Temp Alarm:
An
alarm output that indicates the RF output has been
inhibited, because the sensed temperature in the
AC/DC power supply compartment is in excess of
85
°
C, is available on TB3-7 (
P/S OVER TEMP
). A
negative logic output (current-sink-to-ground) will be
present for an alarm condition.
2.1.11.12 Battery Low Alarm:
An alarm output
that indicates the charge status of the batteries on
the system control PWB has decayed to less than
4.0 VDC and they should be replaced, is available
on TB3-9 (
BATTERY LOW
). A negative logic output
(current-sink-to-ground) will be present for an alarm
condition.
2.1.11.13 External Interlock Alarm:
An alarm
output that indicates the RF output is being inhibited,
because one or more of the external interlock
switches has been opened, is available on TB3-10
(
EXT INTLK OPEN
). A negative logic output (current-
sink-to-ground) will be present for an alarm
condition.
2.1.11.14 Internal Interlock Alarm:
An alarm
output that indicates the RF output is being inhibited,
because the transmitter's ground wand is not
properly stored in its retaining clip, is available on
TB3-11 (
INT INTLK OPEN
). A negative logic output
(current-sink-to-ground) will be present for an alarm
condition.
2.1.11.15 RF Power Shutback Alarm:
An alarm
output that indicates the RF output is being inhibited
(shutback), because a protection circuit threshold has
been exceeded, is available on TB5-1 (
RF PWR
CUTBACK
). A negative logic output (current-sink-to-
ground) will be present for an alarm condition.
2.1.11.16 RF Drive B+ Fail Alarm:
An alarm
output that indicates the RF output has been inhibited,
because the output of the RF drive amplifier's B+
DC power supply is less than 56V, is available on
TB5-2 (
RF DR B+ FAIL
). A negative logic output
(current-sink-to-ground) will be present for an alarm
condition.
2.1.11.17 PDM Failure Alarm:
An alarm output
that indicates the RF output has been inhibited,
because one or both of the pulse duration modulation
(PDM) outputs from the active interphase PDM
driver PWB has failed, is available on TB5-3 (
PDM
FAIL
). A negative logic output (current-sink-to-
ground) will be present for an alarm condition.
2.1.11.18 RF Drive Fail Alarm:
An alarm output
that indicates the RF output has been inhibited,
because the peak-to-peak voltage of the RF drive
being applied to the FETs in the RF amplifiers of the
RF power module is less than 17.5 volts peak-to-
peak, is available on TB5-4 (
RF DRIVE FAIL
). A
negative logic output (current-sink-to-ground) will be
present for an alarm condition.
2.1.11.19 Low DC Volts Fail Alarm:
An alarm
output that indicates the RF output has been inhibited,
because the output of one of the low voltage DC
power supplies (+8V, +5V, -5V, +15V or -15V) has
failed, is available on TB5-5 (
LV P/S FAIL
). A
negative logic output (current-sink-to-ground) will be
present for an alarm condition.
Summary of Contents for XL12
Page 194: ...Figure SD 2 Electrical Schematic Exciter Stage Page SD 2 01 January 2002...
Page 195: ...Figure SD 3 Electrical Schematic RF Drive Stage Page SD 3 01 January 2002...
Page 196: ...Figure SD 4 Electrical Schematic RF Power Stage Page SD 4 01 January 2002...
Page 197: ...Figure SD 5 Electrical Schematic Control Monitor Functions Page SD 5 01 January 2002...
Page 198: ...Figure SD 6 Electrical Schematic AC DC Power Stage Page SD 6 01 January 2002...
Page 199: ...Figure SD 7 Electrical Schematic Remote Interface PWB NAPI25A Page SD 7 01 January 2002...
Page 200: ...Figure SD 8 Electrical Schematic Exciter Interface PWB NAPI22E Page SD 8 01 January 2002...
Page 201: ...Figure SD 9 Electrical Schematic RF Drive Tuning PWB NAPI60 Page SD 9 01 January 2002...
Page 202: ...Figure SD 10 Electrical Schematic Distribution PWB NAPI50B Page SD 10 01 January 2002...
Page 203: ...Figure SD 11 Electrical Schematic DC Power Supply PWB NAPS16C Page SD 11 01 January 2002...
Page 210: ...Figure MD 3 Assembly Detail NAC101 Control Monitor Panel Page MD 3 01 January 2002...
Page 212: ...Figure MD 5 Assembly Detail NAPI25A Remote Interface PWB Page MD 5 01 January 2002...
Page 213: ...Figure MD 6 Assembly Detail NAE73A Exciter Panel Page MD 6 01 January 2002...
Page 214: ...Figure MD 7 Assembly Detail NAPI22E Exciter Interface PWB Page MD 7 01 January 2002...
Page 215: ...Figure MD 8 Assembly Detail NAE83 RF Drive Panel Page MD 8 01 January 2002...
Page 216: ...Figure MD 9 Assembly Detail NAAA02 RF Drive Amplifier Page MD 9 01 January 2002...
Page 219: ...Figure MD 11 Assembly Detail NAPS10B Regulated Power Supply PWB Page MD 11 01 January 2002...
Page 220: ...Figure MD 12 Assembly Detail NAPI50B Distribution PWB Page MD 12 01 January 2002...
Page 221: ...Figure MD 13 Assembly Detail Fan Tray P N 183 8350 Page MD 13 01 January 2002...
Page 222: ...Figure MD 14 Assembly Detail NAF102 RF Output Filter Top View Page MD 14 01 January 2002...
Page 223: ...Figure MD 15 Assembly Detail NAF102 RF Output Filter Rear View Page MD 15 01 January 2002...
Page 224: ...Figure MD 16 Assembly Detail NAFP90 Forward Reflected Power Probe Page MD 16 01 January 2002...
Page 225: ...Figure MD 17 Assembly Detail NAX161 Static Drain Choke Page MD 17 01 January 2002...
Page 228: ...Figure MD 20 Assembly Detail NAPP02 RF Current Probe PWB Page MD 20 01 January 2002...
Page 229: ...Figure MD 21 Assembly Detail Capacitive Divider Assembly 176 8253 Page MD 21 01 January 2002...
Page 231: ...Figure MD 23 Assembly Detail NASR108 AC DC Power Supply Top View Page MD 23 01 January 2002...
Page 232: ...Figure MD 24 Assembly Detail NASR105 01 Power Transformer Assembly Page MD 24 01 January 2002...
Page 233: ...Figure MD 25 Assembly Detail 3 Rectifier UP28 Page MD 25 01 January 2002...
Page 234: ...Figure MD 26 Assembly Detail NAPS16C DC Power Supply PWB Page MD 26 01 January 2002...
Page 235: ...Figure MD 27 Assembly Detail NAPI48B DC Power Supply Monitor PWB Page MD 27 01 January 2002...