VS300 Installation Manual
Connecting ac power
Issue 6.0 2014-11-01
Page 5-1
Section 5:
Connecting ac power
To connect ac power to the transmitter, perform the following steps:
1. Switch off the ac power at the service entrance.
2. Obtain the ac power cord (Nautel Part # JD43) and two 85.7 mm ferrite toroids (Nautel Part
# LP23) from the installation kit.
3. Pass the ac power cord through the ferrite toroids. If practical, the ac power cord should pass
through a minimum of two times (two turns).
4. Connect the ac power cord to the
AC INPUT
receptacle (U1) on the rear of the VS300.
5. Connect the other end of the ac power cord to the 100 to 240 V ac input source.
6. Verify that the station reference ground is connected to the safety ground stud at the rear of
the VS300.