NV15/NV20 Operations and Maintenance Manual
Operating the transmitter
Page 2-110
Issue 3.2 2013-10-01
•
IPA Voltage
•
Average IPA Output Power
•
Controller Temperature
The values associated with each of these fixed meters (cannot be changed to another meter) are of a
linear nature so that changes made to the
Full Scale Voltage
field (allowable range is 1- 6 V, defaulted
to 6 V) will be reflected in the other fields according to the following equation:
(Current Value/Full Scale Value) x Full Scale Voltage = Current Voltage
Press
Apply
to activate changes. Press
Cancel
to discard changes.
Figure 2.84: Analog Outputs Page
Note:
The Current Voltage reading reflects the value that can be measured at the associated remote
analog output pin for the given Current Value. See the NV series transmitter Pre-installation
Manual for actual remote analog output pin assignments.