I.
General Information
A. Terminology In This Manual
a. Boiler:
Refers to the Nature’s Comfort boiler you purchased
.
b. Furnace:
Refers to an indoor gas or oil fired unit which heats the air for your home. This would
be your existing furnace.
B. Specifications
Type of fuel:
1-2 Years Seasoned Hard, Cordwood only.
Location:
Outdoor use only.
Electrical Rating:
115 VAC, 5A (15A max when convenience outlet is used), 60 HZ
Min. Circuit Breaker:
15 Amp
Draft Blower:
550 CFM, 115 VAC
Water Pump:
115 VAC, 2A max.
C. Clearance to Combustibles Required
Top, Front, Rear and Sides:
36 inches
Flooring:
Non-Combustible
Chimney:
36 inches
D. Boiler Dimensions
& Specifications
300,000 BTU, 220-gallon water tank, 6,000 sq ft.*
45" x 78" x 83" tall, 2,380 pounds
*Will heat up to 7000 sq ft (This must include all heated areas of home as well
as basement.) with proper installation, properly insulated building and
when properly seasoned hardwood is used (20% moisture content).
Deduct a minimum of 500 sq ft if heating domestic hot water.
Firebox Size
Cubic Feet
Height
Width Depth
17.4
30”
28”
40”
Steel thickness:
Water Jacket
Firebox
7ga.
(approx. 3/16”)
¼”