Step 2: Installing the vent pipe & liquid drain
After selecting the toilet
’
s location, fit the Wallace
Grommet to the back of the fibreglass shell. Push
the shell flush against the wall (in the correct position
& alignment). Mark a circle on the wall through the
Wallace Grommet & Liquid Drain Hole as a guide.
Move the Shell away from the wall.
Prepare to drill suitable holes to ac-
commodate the 19mm liquid drain
hose and the 50mm PVC Pipe. Use
these pipes to accurately mark the
diameters on the wall.
Wallace
Grommet
Liquid Drain Hole
Hose removed
Using the circles drawn on the wall as a guide, cut a hole of sufficient size to allow the 50mm pipe
to push through the wall and a second hole (approximately 25mm) for the liquid drain hose.
Push the 50mm PVC pipe length
provided into the
‘
T
’
piece and then
insert the 50mm PVC pipe through
the wall until the
‘
T
’
piece is flat
against the wall.
50mm PVC
Pipe