Installation and Maintenance Manual
16. REMOTE CHILLER MODEL INSTALLATION:
1
2
3
CARBONATED
WATER TAP
STILL WATER TAP
DISPENSE TOWER
4
5
8
6
REMOTE CHILLER
MODEL
FROM CO
2
CYLINDER
FROM FILTER SET
5/16” O.D.
TUBING
5/16” UNION
FITTING
1/4” X 5/16”
REDUCING
FITTING OR
5/16” UNION
FITTING
7
Remote Chiller Model Installation- Connection of the Carbonated Water Tubing.
1.
Insert the 5/16” O.D. tubing into the tubing insulation provided.
2.
Connect the 5/16” O.D tubing to the left elbow quick connect
fi
tting on the front of the
unit.
3.
Connect the other end of the 5/16” O.D. tubing to the inlet of the Flow Compensator.
4.
Connect the outlet of the Flow Compensator to the left side union
fi
tting on the
Dispense Tower. Note: This
fi
tting may be a 1/4” x 5/16” reducing
fi
tting or 5/16” union
fi
tting depending on the Dispense Tower model.
STILL WATER
CARBONATED WATER
FLOW COMPENSATOR
( ADJUST TO I LITER / 15 SECONDS )
NOTE:
FLOW COMPENSATOR MUST BE
ADJUSTED PER INSTRUCTIONS
FOUND IN SECTION 17.