5110 MACHINE MAINTENANCE
MOTOR OVERLOAD SWITCH
Motor is equipped with a thermal overload switch. Switch will trip if motor runs too hot.
1. Let motor cool off.
2. Depress red button on end of motor junction box located on motor under the hood. Switch presses hard.
ELECTRICAL BOX
To Replace Electrical Box
1. Disconnect machine from power.
2. Remove hood.
3. Disconnect back-up beeper switch wiring.
4. Disconnect seat switch wires.
5. Remove two ¼" electrical box securing nuts.
6. Remove electrical box.
HYDRAULIC CYLINDER CHANGE OUT
1. Disconnect machine from power.
2. Disconnect cylinder lines. Have a container ready to catch oil from lines.
3. Remove cylinder securing hexhead bolt from lower cutting head support.
4. Remove clips and pin from cylinder and slide plate.
5. Remove cylinder upper pin.
6. Remove cylinder.
ELECTRICAL CORD
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly
qualified person in order to avoid a hazard.
Motor Cord
Outlets
Starting
Switches
Shut Off
Switch
“Kill Switch”