background image

These  Evaluation  Boards  are  intended  for  product  evaluation  purposes  only  and  are  not  intended  for  resale  to  end

consumers, is not authorized for such use and is not designed for compliance with European EMC Directive 89/336/EEC.

National does not assume any responsibility for use of any circuitry or software supplied or described. No circuit patent

licenses are implied.

LIFE SUPPORT POLICY

NATIONAL'S  PRODUCTS  ARE  NOT  AUTHORIZED  FOR  USE  AS  CRITICAL  COMPONENTS  IN  LIFE  SUPPORT

DEVICES  OR  SYSTEMS  WITHOUT  THE  EXPRESS  WRITTEN  APPROVAL  OF  THE  PRESIDENT  OF  NATIONAL

SEMICONDUCTOR CORPORATION. As used herein:
1. Life  support  devices  or  systems  are  devices  or

systems which, (a) are intended for surgical implant

into  the  body,  or  (b)  support  or  sustain  life,  and

whose  failure  to  perform,  when  properly  used  in

accordance with instructions for use provided in the

labeling, can be reasonably expected to result in a

significant injury to the user.

2. A  critical  component  is  any  component  in  a  life

support device or  system  whose  failure  to  perform

can be reasonably expected to cause the failure of

the  life  support  device  or  system,  or  to  affect  its

safety or effectiveness.

National Semiconductor Corporation

Americas

Tel:      1-800-272-9959

Fax:     1-800-737-7018

Email: [email protected]

National Semiconductor Europe

Fax: +49 (0) 1 80-530 85 86

Email: [email protected]

Deutsch Tel: +49 (0) 1 80-530 85 85

English   Tel: +49 (0) 1 80 532 78 32

Français Tel: +49 (0) 1 80 532 93 58

Italiano   Tel: +49 (0) 1 80 534 16 8

National Semiconductor

Asia Pacific Customer

Response Group

Tel:  65-2544466

Fax: 65-2504466

Email: [email protected]

National Semiconductor

Japan Ltd.

Tel:   81-3-5620-6175

Fax:  81-3-5620-6179

www.national.com

National does not assume any responsibility for any circuitry described, no circuit patent licenses are implied and National reserves the right

at any time without notice to change said circuitry and specifications.

              

12

          

http://www.national.com

Summary of Contents for ADC122S101

Page 1: ...to Digital Converters with Input Multiplexer ADC122S101 ADC102S101 ADC082S101 ADC122S051 ADC102S051 ADC082S051 ADC122S021 ADC102S021 ADC082S021 ADC124S101 ADC104S101 ADC084S101 ADC124S051 ADC104S051...

Page 2: ...talling and Using the ADCxx1S101 Evaluation Board 5 5 1 Software Installation 5 5 2 Setting up the ADCxx1S101 Evaluation Board 5 5 2 1 Board Set up 5 5 2 2 Quick Check of Analog Functions 5 5 2 3 Quic...

Page 3: ...e also computes and displays dynamic performance in the form of SNR SINAD THD SFDR and ENOB 2 Connect a clean power supply to the terminals of connector P1 Adjust power supply to a voltage of 5 5V to...

Page 4: ...both through an appropriate filter s These 50 Ohm inputs are intended to accept a low noise sine wave signal of peak to peak amplitude up to the power supply level To accurately evaluate the ADC dynam...

Page 5: ...nect The evaluation board to a WaveVision4 Capture Board WAVEVSN BRD 4 0 Pin 1 of P1 5 5V to 5 7V at 50 mA Pin 2 of P1 Ground 2 Connect the desired jumper to JP1 JP2 JP3 and JP4 See Section 4 8 4 8 An...

Page 6: ...d not be used for coherent sampling 9 With the mouse you may click on the magnifying glass then and drag top left to bottom right to select a portion of the displayed waveform for better examination 5...

Page 7: ...of TP1 Be sure that only one clock source oscillator at Y1 or signal at BNC3 is active on the board 6 0 Evaluation Board Specifications Board Size 3 1 x 3 8 8 0 cm x 9 6 cm Power Requirements 5 5V to...

Page 8: ...COUP EEPROM_Power AIN3 JP6 HEADER 3X1 1 2 3 ADC_SCLK ADC_SCLK C19 10uF 6 3V JP1 IN1_SEL 1 3 5 2 4 6 JP2 IN2_CH_SEL 1 2 3 4 5 6 7 8 TPG4 GND 1 C12 10uF 6 3V AIN1 R3 51 1 C18 0 1 uF L2 100 uH Choke ADC_...

Page 9: ...Block DigiKey ED1609 ND 15 2 Q1 Q2 MMBTN3904 SOT 23 Various 16 2 R2 R3 51 1 1 1 8 Watt Size 0603 17 1 R4 0 Size 0603 18 1 R5 1 8k 5 1 10 W Size 0603 19 2 R6 R7 1k 5 1 10 W Size 0603 20 2 VR1 VR2 1k Di...

Page 10: ...und 8 Ground 10 Ground JP1 Input 1 Select Jumper Function none Input 1 not connected to DUT 1 2 Input 1 a c coupled 3 4 Input 1 path grounded 5 6 Input 1 d c coupled JP2 Input 1 Channel Select Jumper...

Page 11: ...n the Evaluation Board Test Point Function TP 1 DUT supply voltage TP 2 ADC CSb TP 3 ADC DIN TP 4 ADC DOUT TP 5 SCLK TP 6 INPUT1 Signal input to DUT TP 7 INPUT2 Signal input to DUT TP 8 Board 5 5V Sup...

Page 12: ...can be reasonably expected to result in a significant injury to the user 2 A critical component is any component in a life support device or system whose failure to perform can be reasonably expected...

Page 13: ...or use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have...

Reviews: