![National Security Systems D636 User Manual Download Page 5](http://html.mh-extra.com/html/national-security-systems/d636/d636_user-manual_710354005.webp)
EXIT NOW
BYPASS 123456789
10->16 0123456
READY TO ARM
(custom text)
Selective Zone Shunting
Selective Zone Shunting
will
be reported to the Central Station.
Selective Zone Shunting
will not
be reported to the Central Station.
The Command Center makes it easy for you to have complete control of
your security system. By using Selective Zone Shunting you have the
ability to bypass zones you do not wish to arm, directly from the Command
Center. With the push of a button, the Command Center displays which
zones are going to be armed. If you don't want a particular zone to arm,
simply push the same numbered key as that zone, press
ENT
, and it
will not arm with the rest of the system.
Application
In an office building or warehouse, Selective Zone Shunting enables you
to arm only those areas that need to be kept secure. Areas where personnel
are working can be kept disarmed until they are finished and the areas
vacated. To arm all zones, simply disarm the unit and rearm using one of
the arming commands or your personal passcode plus
ENT
.
Using COMMAND 0:
Display:
1. Ensure that all zones are secure.
2. Start the system exit delay by entering your personal passcode plus
ENT
, or an
arming command
which provides exit delays. The
ARMED
light flashes, indicating the start of the exit delay time.
COMMAND
0
3. While the system is in the exit delay
mode, press the
COMMAND
bar
and then the
0
.
The system is now in the Selective Zone Shunting mode. Zones 1-9 are
displayed on the top line of the display and zones 10-16 are displayed
on the bottom line. (Priority and 24 hour zones cannot be bypassed.)
4. To
prevent
a zone from being armed, press the key that corresponds
with the number of that zone and then the
ENT
key. The number
pressed will disappear from the screen.
During the exit time, if you decide you want to arm a zone that you
bypassed, press the number key that corresponds to the zone, and then
the
ENT
key. The number of that zone will reappear in the display.
Each time a zone number key is pressed while in this mode, the exit
time is restarted.
5. After all zone arming selections have
been made, press the
ENT
key to
enter your commands and terminate
the Selective Zone Shunting mode.
6. The
ARMED
indicator will remain lit when the delay time has expired
and the system becomes armed.