Changing battery type
5
This is best done before the battery is installed into the Power Pack DC.
The battery type should be chosen before the auxiliary battery is installed.
For safety, the battery type cannot be changed if the auxiliary battery is already connected.
A power source connected to the MAIN BATT or SOLAR PANEL input is required to change the battery
type.
Wet
AGM / Gel
Ca+
Li-ion
Used for automotive Lithium-ion or
LiFePO4 batteries.
Used for regular automotive starting
and flooded high-cycle batteries.
Used for flooded deep-cycle, calcium
and maintenance-free batteries.
Used for all types of AGM and Gel
batteries.
DC-DC Battery Charger
Battery
Float
Li-ion
Wet
Ca+
AGM/Gel
Charge
OK /
Left side
Right side
1
3
4
2
Remove screws from the left, right and under-side as
indicated.
The cover can now hinge open.
The cover can now be opened fully to expose the
internal DC-DC system.
With the cover slightly open, unplug the remote
monitor cable.
Connect power to the MAIN BATT or SOLAR input.
The DC-DC system will now activate and show the
current battery selection.
Remove the cover of the internal DC-DC system by
loosening two screws on top.
Once the preferred battery type is selected, disconnect
the power source.
- Replace the cover of the DC-DC system.
- Re-connect the remote monitor plug and close the cover.
- Re-install the screws that were removed earlier.
- The auxiliary battery can now be installed.
Battery Types
5
6
The AGM battery type
is the default factory
setting.
To change this, press
the "Battery" button
until the desired type is
selected.