![National Luna Portable Power Pack II Owner'S Manual Download Page 12](http://html.mh-extra.com/html/national-luna/portable-power-pack-ii/portable-power-pack-ii_owners-manual_710265012.webp)
Adjusting Alarm and Timer values
Device status and warnings
The alarm can be adjusted
between 10.0V and 11.9V.
Press OK when done or
anywhere else on the screen to
cancel.
The alarm voltage can be
adjusted by pressing the + or -
buttons shown at the bottom.
To adjust the low-battery alarm
voltage, tap the alarm button.
To adjust the start timer, tap the
timer button.
The timer can be adjusted
between 0:30 and 8:00.
Press OK when done or
anywhere else on the screen to
cancel.
The start timer can be adjusted
by pressing the + or - buttons.
Standby - The system is isolating the main and auxiliary batteries.
No charge or discharge currents are detected.
The Start Timer is active and will run for the configured duration.
Start Delay - The system has detected that the vehicle has started.
Paused - If the vehicle has been turned off before the Start Timer has
completed, the system enters a paused state. If the vehicle re-starts
during this state, the Start Timer will resume.
Charging - The auxiliary battery is receiving charge. The charge current
is shown on the dashboard.
Discharging - The auxiliary battery is being discharged. The discharge
current is showed on the dashboard.
Battery Low- The auxiliary battery voltage is below the configured low-
voltage threshold.
Charger Connected - A charge source is connected to the secondary
charge input and the auxiliary battery is being charged.
eg. An external battery charger is connected to the charge port.
START DELAY
PAUSED
CHARGING
DISCHARGING
BATTERY LOW
CHARGER CONNECTED
STANDBY
11