Appendix B
Advanced Hardware Configuration Settings
©
National Instruments
B-7
VXI-MXI-Express Series User Manual
Inverting CLK10
If the front panel SMB connector EXT CLK is configured as an output this
software setting provides the capability to invert the clock output. This
setting can be found in the hardware configuration panels in MAX as
shown in Figure B-4.
Figure B-4.
Inverting the CLK10 Signal through MAX
CLK10 Termination
If the front panel SMB connector EXT CLK is configured as an input
this software setting can enable 50
Ω
parallel termination. This setting
can be found in the hardware configuration panels in MAX, as shown in
Figure B-4.
Front Panel/SMB Trigger Input Termination
Optional software enabled 50
Ω
parallel termination is available for the
front panel trigger input. This setting can be found in the hardware
configuration panels in MAX, as shown in Figure B-4.
Note
Parallel termination is not necessary when the signal is driven by a 50
Ω
source,
such as a NI VXI-8360T/LT controller.