Chapter 2
Hardware Configuration and Installation
© National Instruments Corporation
2-19
VXI-AT2000/NI-VXI MS-DOS Getting Started
your additional VXI-MXIs for more information. You can change the logical address of the
VXI-MXI by changing the setting of the 8-bit DIP switch labeled LOGICAL ADDRESS SWITCH
on the front panel. The ON position on the DIP switch corresponds to a logic value of 0, and the
OFF position corresponds to a logic value of 1. Verify that the VXI-MXI does not have the
same logical address as any other statically configured VXIbus device in your system.
Remember that logical addresses hex 0 and FF are not allowed for the VXI-MXI.
Figure 2-10 shows switch settings for logical address hex 1 and C0.
Shown at
Default setting
of Logical Address 1
LOGICAL ADDRESS
SWITCH
Push this side down for logic 0
Push this side down for logic 1
OFF
ON
1
2
3
4
5
6
7
8
OFF
1
2
3
4
5
6
7
8
a. Switch Setting to Default Setting Logical Address
Shown at
Default setting
of Logical Address 1
LOGICAL ADDRESS
SWITCH
Push this side down for logic 0
Push this side down for logic 1
OFF
ON
1
2
3
4
5
6
7
8
OFF
12
34
5
6
7
8
b. Switch Set to Logical Address hex C0
Figure 2-10. Logical Address Selection
VMEbus Request Level Selection
The VXI-MXI uses one of the four VMEbus request levels to request use of the VME Data
Transfer Bus (DTB). The VXI-MXI requests use of the DTB whenever an external MXIbus