Connecting to the DAQ Device
The following sections describe how to connect the SCC-68 to the DAQ
device. The SCC-68 is designed to be used with M Series and E Series
DAQ devices only. Other 68-pin devices may not function properly with
the SCC-68.
Using the SCC-68 with 16 AI Channel M Series Devices
To use the SCC-68 with a 16 AI channel M Series device, complete the
following steps:
1.
Attach the quick reference guide, shown in Figures 21 and 22, to the
top of the SCC-68 enclosure as shown in Figure 1. The quick reference
guide for Connector 0 (included in the SCC-68 kit) shows the pin
assignments of the SCC-68 and other useful information.
2.
Attach the SCC-68 to the DAQ device using one of the following
cables:
•
SHC68-68-EPM
•
SHC68-68
•
RC68-68
3.
Proceed to the
Taking Measurements with NI-DAQmx
section for
information about using the SCC-68 in measurement applications.
Note
Some M Series devices are available with a 37-pin connector. The SCC-68 cannot
be used with these devices.
Using the SCC-68 with 32 AI Channel M Series Devices
The 32 AI channel M Series DAQ device has two connectors.
•
Connector 0 (AI 0-15)
•
Connector 1 (AI 16-31)
The SCC-68 can be used with Connector 0 or Connector 1.
To use the SCC-68 with a 32 AI channel M Series device using
Connector 0, complete the following steps:
1.
Attach the quick reference guide, shown in Figures 21 and 22, to the
top of the SCC-68 enclosure as shown in Figure 1. The quick reference
guide for Connector 0 (included in the SCC-68 kit) shows the pin
assignments of the SCC-68 and other useful information.