background image

©

 National Instruments Corporation

13

NI PMA-1115 User Guide and Specifications

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 662 457990-0, 
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, 
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, 
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, 
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, 
Poland 48 22 3390150, Portugal 351 210 311 210, Russia 7 495 783 6851, 
Singapore 1800 226 5886, Slovenia 386 3 425 42 00, 
South Africa 27 0 11 805 8197, Spain 34 91 640 0085, 
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, 
Taiwan 886 02 2377 2222, Thailand 662 278 6777, 
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545

Summary of Contents for Portable Monitor Accessory NI PMA-1115

Page 1: ...key English keyboard and touchpad Hardware for mounting to NI 8 slot PXI chassis Anti glare tempered glass for LCD protection VGA and DVI connectivity to the LCD USB connectivity to the touch screen k...

Page 2: ...ng kit for attachment to any NI 8 Slot PXI chassis This kit contains an adapter plate with provisions to relocate the carrying handle as well as all required fasteners Complete the following instructi...

Page 3: ...g the Handle 3 Remove the handle from the chassis Retain the handle Discard the screws 4 Attach the adapter plate to the chassis using the supplied M4 8 pan head screws as shown in Figure 3 Figure 3 I...

Page 4: ...all the handle using the supplied 4 40 5 16 pan head screws as shown in Figure 4 Reinstall the handle covers by snapping them over the handle mounting plates Figure 4 Reinstalling the Handle and Handl...

Page 5: ...Figure 5 Install the remaining M4 8 pan head screws Figure 5 Installing the PMA 1115 7 Open the keyboard and LCD as shown in Figure 6 Install the supplied 6 32 3 8 flat head screws in the lower corne...

Page 6: ...AC Adapter Note Do not place the AC adapter over any vent holes on the chassis cover as this may cause chassis cooling issues System Configuration The On Screen Display OSD controls on the side of th...

Page 7: ...erican 240 VAC 763068 01 Japanese 100 VAC 763634 01 United Kingdom 240 VAC 763064 01 Swiss 220 VAC 763065 01 Australian 240 VAC 763066 01 Universal Euro 240 VAC 763067 01 Specifications AC DC Adapter...

Page 8: ...down 160 right and left Control system On screen display Connectivity VGA or DVI I Keyboard and Mouse Keyboard 105 key English language Mouse Touchpad Connectivity USB Mechanical Overall dimensions 1...

Page 9: ...limit Relative humidity range 10 to 90 noncondensing Refer to Figure 8 for the correlation between temperature and humidity Tested in accordance with IEC 60068 2 56 Storage Environment Ambient tempera...

Page 10: ...ith IEC 60068 2 27 Random Vibration Operating 5 to 500 Hz 0 31 grms Nonoperating 5 to 500 Hz 2 46 grms Tested in accordance with IEC 60068 2 64 Nonoperating test profile exceeds the requirements of MI...

Page 11: ...he following standards of EMC for electrical equipment for information technology equipment EN 55024 CISPR 24 EN 55022 CISPR 22 CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance...

Page 12: ...e at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electrical...

Page 13: ...48 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 662 457990 0 Belgium 32 0 2 757 0020 Brazil 55 11 3262 3599 Canada 800 433 3488 Ch...

Page 14: ...right Under the copyright laws this publication may not be reproduced or transmitted in any form electronic or mechanical including photocopying recording storing in an information retrieval system or...

Page 15: ...al Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the a...

Reviews: