Getting Started with the NI PCI-8254R

The NI 8254R ships with a 2-position power connector that plugs directly into the isolated outputs 
power input connector on the NI 8254R. To wire power to the 2-position connector, complete the 
following steps:

1.

Wire the voltage output of the isolated power supply to the isolated outputs power input, labeled 

V

on the 2-position connector.

2.

Wire the common-mode signal (ground) output of the power supply to the isolated outputs 
common-mode signal input, labeled 

C

, on the 2-position connector.

Configuring the NI 8254R

After you have installed the NI 8254R and powered on your computer, Windows will recognize the 
device and assign resources to it. Use Measurement & Automation Explorer (MAX), the National 
Instruments configuration utility, to configure the IEEE 1394 camera connected to the NI 8254R for 
acquisition. Refer to the 

Measurement & Automation Explorer Help for NI-IMAQdx

 for additional 

information about configuring the NI 8254R.

Note

Before configuring the device in MAX, ensure that you installed the NI-IMAQdx driver 

software.

Specifications

The following specifications apply to the NI IEEE 1394a interface device. These specifications are 
typical at 25 °C, unless otherwise stated.

TTL Inputs and Outputs

Digital logic levels

TTL Inputs

Number of channels ...............................................2

Maximum pulse rate ..............................................2 MHz

Minimum pulse detected........................................500 ns

Power-on state........................................................Input (high-impedance) 61.9 k

Ω

pull-up to 5V

TTL Outputs

Number of channels ...............................................10

Output voltage range..............................................0 V to 5 V

Maximum pulse rate ..............................................2 MHz

Level

Minimum

Maximum

Input low voltage (V

IL

)

0 V

0.5 V

Input high voltage (V

IH

)

2.2 V

5 V

Output low voltage (V

OL

), at 5 mA

0.4 V

Output high voltage (V

OH

), at 5 mA

2.4 V

Summary of Contents for NI VISION PCI-8254R

Page 1: ...PCI 8254R...

Page 2: ...ndows Vista NI Vision Acquisition Software 8 2 1 or later which includes the NI IMAQdx and NI IMAQ I O driver software Optional software for developing applications NI Vision Builder for Automated Ins...

Page 3: ...he LabVIEW Help Safety Information Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner...

Page 4: ...lse withstand voltage levels that commonly occur in electrical distribution systems The following is a description of Measurement Installation3 Categories Measurement Category I is for measurements pe...

Page 5: ...uter Store the NI 8254R in the antistatic package when not in use Installation The following instructions are for general installation Refer to the documentation provided by your computer manufacturer...

Page 6: ...o an IEEE 1394a connector on the NI 8254R front panel Refer to Figure 1 for the location of the IEEE 1394a connectors on the NI 8254R 12 Plug in and power on the computer The NI 8254R is now installed...

Page 7: ...Figure 3 b Reconnect the wire that was connected to the C position on the 4 position power connector to the C position on the 2 position isolated outputs power connector shown in Figure 3 Figure 2 Rem...

Page 8: ...power supply cable around the ferrite two times as shown in Figures 4 and 5 Figure 4 Installing a Ferrite Connector on the Power Supply Cable Figure 5 Closed Ferrite on the Power Supply Cable 4 Plug t...

Page 9: ...cturer specifications to terminate the wires leading to the 2 position power connector shown in Figure 7 Ferrules are available from Phoenix Contact part number 3200519 Figure 7 Wiring a Third Party P...

Page 10: ...orer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8254R for acquisition Refer to the Measurement Automation Explorer Help for NI IMAQdx for...

Page 11: ...Hz maximum load resistance 100 k Minimum pulse generated 100 s Reverse polarity protection Yes IEEE 1394 Number of ports 2 Speed 100 200 or 400 Mbps Power Requirements IEEE 1394 bus power1 18 W maximu...

Page 12: ...electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For...

Page 13: ...ts calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 787...

Reviews: