background image

© 2014 National Instruments. All rights reserved. 

374811A-01

Sep14

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

After the move has been stopped, errors are cleared and the motion reference is destroyed.

Figure 11.  

Destroying Move Reference

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 

Communities using the manufacturer’s declaration of conformity. This system affords the user 

protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 

for your product by visiting 

ni.com/certification

If your product supports calibration, 

you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 

Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 

telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 

Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 

events.

Summary of Contents for NI SMD-7613

Page 1: ...and Configuration 3 Step 1 Connect the Drive to the NI PS 12 13 Power Supply 3 Step 2 Connect the SMD to the Motor 4 Step 3 Connect the Drive to the Network 7 Step 4 Verify the Connections 11 Using th...

Page 2: ...Motion Module in LabVIEW To access this help file from LabVIEW select Help LabVIEW Help then expand the LabVIEW NI SoftMotion Module book on the Contents tab LabVIEW Help Use the LabVIEW Help to acces...

Page 3: ...e end of the V wire to the corresponding terminal on the included power connector Tighten the screw to ensure a secure connection 4 Connect one end of a 1 02 mm to 0 81 mm diameter 18 to 20 AWG gauge...

Page 4: ...leads present Refer to the following figures to connect your stepper motor Note Motor wire colors are correct for NI stepper motors compatible with the NI SMD 761x These wire colors may not match a th...

Page 5: ...n be connected in series or center tap Figure 3 Six Lead Motor Connected in Series Figure 4 Six Lead Motor Connected in Center Tap Phase A Green White No Connect No Connect Phase A Grn Wht Phase B Red...

Page 6: ...be connected in series or parallel Figure 5 Eight Lead Motor Connected in Series Figure 6 Eight Lead Motor Connected in Parallel Phase B Phase A Phase A Phase B Orange Org Wht Blk Wht Black Red Red W...

Page 7: ...he factory default address for each switch setting is shown in the table below The IP address corresponding to positions 1 through E can be changed using the NI Stepper Configuration Utility software...

Page 8: ...figuration Many networks use dynamic addressing where a DHCP server assigns addresses on demand The address you choose for your device might get assigned to something else by the DHCP server at anothe...

Page 9: ...mpatible with your PC However you will not know what address the server assigns to the device The NI Stepper Configuration Utility can find your device using the Drive Discovery feature as long as you...

Page 10: ...e s IP address to this interface card 6 Next enter the subnet mask as 255 255 255 0 7 Leave Default gateway blank This prevents your PC from looking for a router on this subnet Note Because you are co...

Page 11: ...r Configuration Utility 2 Locate the drive 3 Open the Drive menu and select Self Test 4 Click Start The motor should begin to move Click Stop to finish the test If the motor failed to move verify the...

Page 12: ...all the settings are configured run the VI and click the Start Move button The motor should turn according to the configured move Click the Stop Move button to stop the motor and the Stop VI when you...

Page 13: ...Worldwide Support and Services The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application dev...

Reviews: