background image

REM-11100 Pinout

AI0+ to AI3+

AI0– to AI3–

GND

00

10

20

30

01

11

21

31

02

12

22

32

03

13

23

33

24 VDC

24 VDC

GND

GND

a1

a2

b2

b1

U

IS

0 to U

IS

3

Table 2. REM-11100 Signal Descriptions

Signal

Color

Description

 

 

 

a1, a2

Red

24 VDC (U

A

) Supply for analog modules (internally jumpered)

b1, b2

Blue

GND

Reference potential of the supply voltage (internally
jumpered)

00 to 03 Orange AI0+ to AI3+ Positive voltage connection for channel 0 to 3

10 to 13

AI0- to AI3-

Negative voltage connection for channel 0 to 3

20 to 23

U

IS

0 to U

IS

3

24 V sensor supply for channel 0 to 3

30 to 33

GND

Reference potential of sensor supply

REM-11100 Getting Started Guide

  | 

© National Instruments

  | 

7

Summary of Contents for NI REM-11100

Page 1: ...ight not meet the same safety ratings Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Caution Do not operate the REM 11100 in a manner not specified in this document Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is dam...

Page 2: ...tromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in residential or commercial areas To minimize interference with radio and television reception and prevent unacceptable performance degradation install and use thi...

Page 3: ...ng the device ground yourself using a grounding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the device from the package and inspect the device for loose components or any other sign of damage Caution Never touch the exposed pins of connectors Note Do not install a device if it appears damaged in...

Page 4: ...LED indicators Table 1 Module Function Labels Label Color Module Function Blue Digital input Red Digital output Green Analog input thermocouple Yellow Analog output White Bus coupler power module Installing Bus Connectors What to Use Bus connector DIN rail What to Do Complete the following steps to install bus connectors on the DIN rail 4 ni com REM 11100 Getting Started Guide ...

Page 5: ... bus connector Note A bus connector will not attach to a preceding bus connector with a mounted module Remove the preceding module before installing additional bus connectors 3 Repeat Steps 2 and 3 for additional bus connectors Installing the Module What to Use REM 11100 Mounted bus connector What to Do Complete the following steps to install the REM 11100 on the DIN rail REM 11100 Getting Started...

Page 6: ...n the underside of the module 2 Press the REM 11100 directly onto the bus connector and DIN rail until it clicks into place Caution Tilting the module when mounting it on the DIN rail will damage the contacts Installing Spring Terminal Blocks What to Use REM 11100 Spring terminal block What to Do Align the spring terminal block over the REM 11100 and press until it clicks into place 6 ni com REM 1...

Page 7: ...ply for analog modules internally jumpered b1 b2 Blue GND Reference potential of the supply voltage internally jumpered 00 to 03 Orange AI0 to AI3 Positive voltage connection for channel 0 to 3 10 to 13 AI0 to AI3 Negative voltage connection for channel 0 to 3 20 to 23 UIS0 to UIS3 24 V sensor supply for channel 0 to 3 30 to 33 GND Reference potential of sensor supply REM 11100 Getting Started Gui...

Page 8: ... not detect a valid cycle after power on Flashing The REM 11100 is not part of the configuration Red Solid The REM 11100 has lost connection to the Bus Coupler Flashing The REM 11100 has lost connection to the preceding adjacent module Off The REM 11100 is in reset mode UA Green Solid Supply for analog modules UA present Off No Supply for analog modules UA E1 Red Solid Supply for analog modules UA...

Page 9: ... AI 0 3 UIS 0 3 GND 24 VDC Sensor GND x4 REM 11100 a1 a2 b1 b2 UIS and GND are optional sensor dependent connections Note For information about fuse ratings for the REM 11100 refer to the device datasheet on ni com manuals Connection Guidelines Always connect analog signals using shielded twisted pair cables Unshielded cables may lead to values outside the specified tolerance limits in environment...

Page 10: ... Components Removing Spring Terminal Blocks Complete the following steps to remove a spring terminal block from the REM 11100 1 3 2 1 Press the locking latch to release the spring terminal block 2 Tilt the block toward the center of the module 3 Remove the connector from the module Removing the REM 11100 Remove all connections before removing the REM 11100 either by disconnecting the cables or rem...

Page 11: ...ote You must remove the preceding module before removing the bus connector 1 3 2 1 Slide the bus connector away from the preceding bus connector at least 5 0 mm 0 20 in 2 Insert the screwdriver and loosen both latches on one side of the DIN rail 3 Rotate the bus connector to remove it from the DIN rail Note If you want to remove a bus connector in the middle of the system you must remove any modul...

Page 12: ...ers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufactur...

Page 13: ...sit the Worldwide Offices section of ni com niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events REM 11100 Getting Started Guide National Instruments 13 ...

Page 14: ...d party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Governme...

Reviews: