9.

On the front panel, locate the numeric control labeled 

AO Voltage (bits)

. Right-click the control, 

select 

Replace

 from the shortcut menu, and select 

Knob

 from the 

Express»Numeric Controls

 

palette to change the control type to knob.

10. On the front panel, click and highlight the value in the lower limit of the knob to change the limit 

to –

32000

. Click and highlight the value in the upper limit to change the limit to 

32000

.

11. Save the VI.

12. Using the terminal block, connect analog output channel 0 to analog input channel 0 

by wiring AI0+ (RMIO pin 68) to AO0 (RMIO pin 55) and AI0– (RMIO pin 34) to 
AOGND0 (RMIO pin 21), respectively.

13. Click the 

Run

 button in 

Analog Input (Host).vi

 and adjust the knob that controls analog output 

channel 0. Notice how the change in voltage affects the reading on analog input channel 0.

Where to Go From Here

The following resources contain information for writing applications and taking measurements with 
R Series Multifunction RIO devices.

Software Documentation

LabVIEW FPGA documentation

Getting Started with LabVIEW FPGA 8.x

—This KnowledgeBase, available at 

ni.com/kb

provides links to the top resources that can be used to assist in getting started with 
programming in LabVIEW FPGA.

FPGA Module

 book in the 

LabVIEW Help

—Select 

Help»Search the LabVIEW Help

 in 

LabVIEW to view the 

LabVIEW Help

. Browse the 

FPGA Module

 book in the 

Contents

 tab 

for information about how to use the FPGA Module to create VIs that run on the NI 78

xx

device.

LabVIEW FPGA Module Release and Upgrade Notes—

Contains information about installing 

the LabVIEW FPGA Module, describes new features, and provides upgrade information. 
To access this document, refer to 

ni.com/manuals

. In LabVIEW 8.0 or later, you can 

also view the LabVIEW Manuals directory that contains this document by selecting 

Start»

All Programs»National Instruments»LabVIEW»LabVIEW Manuals

.

Summary of Contents for NI PXI-7851

Page 1: ...PXI 7851...

Page 2: ...Devices NI 78xxR Required Components The following items are necessary to set up and use the NI 78xxR The following software packages LabVIEW LabVIEW FPGA Module NI RIO device drivers Optional LabVIEW...

Page 3: ...uctions for the NI RIO driver The listed documents are available at ni com manuals In LabVIEW 8 0 or later you can also view the LabVIEW Manuals directory that contains these documents by selecting St...

Page 4: ...irst Safety and Electromagnetic Compatibility document packaged with your PXI chassis or device before removing equipment covers or connecting or disconnecting any signal wires 2 Remove the computer c...

Page 5: ...R replace the computer cover if applicable 7 Plug in and power on the computer or PXI chassis To confirm that your device is recognized complete the following additional steps 1 Select Start All Progr...

Page 6: ...D DGND DGND DGND 5V 5V DIO28 DIO31 DIO33 DIO35 DIO37 DIO39 DIO0 DIO2 DIO3 DIO5 DIO6 DIO7 DIO8 DIO1 DIO4 DIO9 DIO10 DIO11 DIO12 DIO13 DIO14 DIO15 DIO16 DIO17 DIO18 DIO19 DIO20 DIO21 DIO22 DIO23 DIO24 D...

Page 7: ...1 AI5 1 AIGND4 AI4 1 AI3 AIGND2 AI2 AI1 AIGND0 AI0 35 1 36 2 37 3 38 4 39 5 40 6 41 7 42 8 43 9 44 10 45 11 46 12 47 13 48 14 49 15 50 16 51 17 52 18 53 19 54 20 55 21 56 22 57 23 58 24 59 25 60 26 6...

Page 8: ...available at ni com manuals Table 1 R Series Connectivity Options Cable Connector Accessory Description NI 781xR NI 783xR 784xR 785xR SHC68 68 RMIO NI Recommended 0 NI SCB 68 High performance shielde...

Page 9: ...projects designed to help you get started using your R Series device 4 Select Basic I O and then select Analog Input R Series lvproj 5 The Analog Input example project opens in the Project Explorer w...

Page 10: ...earlier do not use the Configure Open FPGA VI Reference dialog to update the FPGA target in the host VI For LabVIEW version 8 5 1 and earlier right click the Open FPGA VI Reference function on the bl...

Page 11: ...om the shortcut menu as shown in the following figure 2 In the Project Explorer window right click the FPGA target and select New FPGA I O 3 In the New FPGA I O dialog box expand Connector0 and select...

Page 12: ...from the FPGA Interface palette between the Invoke method and the Read Write Control that already exists on the block diagram c Wire the FPGA VI Reference Out terminal of the Invoke Method node to th...

Page 13: ...channel 0 Where to Go From Here The following resources contain information for writing applications and taking measurements with R Series Multifunction RIO devices Software Documentation LabVIEW FPGA...

Page 14: ...the LabVIEW FPGA platform To access the LabVIEW FPGA IPNet visit ni com ipnet Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com suppo...

Page 15: ...er product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate locatio...

Reviews: