background image

Hazardous Locations

U.S. (UL)

Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, AEx nA IIC T4

Canada (C-UL)

Class I, Division 2, Groups A, B, C, D, T4;
Class I, Zone 2, Ex nA IIC T4

Europe (ATEX) and International (IECEx)

Ex nA IIC T4 Gc

Safety and Hazardous Locations Standards

This product is designed to meet the requirements of the following electrical equipment safety
standards for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

EN 60079-0:2012, EN 60079-15:2010

IEC 60079-0: Ed 6, IEC 60079-15; Ed 4

UL 60079-0; Ed 5, UL 60079-15; Ed 3

CSA 60079-0:2011, CSA 60079-15:2012

Note

 

For UL and other safety certifications, refer to the product label or the 

Online

Product Certification

 section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:

EN 61326 (IEC 61326): Class A emissions; Industrial immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

FCC 47 CFR Part 15B: Class A emissions

ICES-001: Class A emissions

Note

 

For the standards applied to assess the EMC of this product, refer to the 

Online Product Certification

 section.

Note

 

For EMC compliance, operate this product according to the documentation.

NI cRIO-9111/9112/9113/9114/9116/9118

  | 

© National Instruments

  | 

17

Summary of Contents for NI cRIO-9111

Page 1: ...is cRIO 9111 9113 This document describes how to install an NI cRIO 9111 cRIO 9112 cRIO 9113 cRIO 9114 cRIO 9116 or cRIO 9118 In this document the NI cRIO 9111 cRIO 9112 cRIO 9113 cRIO 9114 cRIO 9116...

Page 2: ...lly The chassis has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 07 ATEX 0626664X and is IECEx UL 14 0089X certified Each device is marked II 3G and is suitable for use in Zone 2 hazardous...

Page 3: ...n and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install the product in a shielded enclosu...

Page 4: ...learn the basics of LabVIEW software LabVIEW Help access information about LabVIEW programming concepts step by step instructions for using LabVIEW and reference information about LabVIEW VIs functio...

Page 5: ...5 lb in of torque Mounting the CompactRIO Reconfigurable Embedded Chassis You can mount the chassis on a panel on a 35 mm DIN rail on a rack in an enclosure or on a desktop Use the DIN rail mounting m...

Page 6: ...Allow 25 4 mm 1 in on the top and the bottom of the chassis for air circulation Allow 50 8 mm 2 in in front of modules for cabling clearance for common connectors such as the 10 terminal detachable s...

Page 7: ...0 in 93 1 mm 3 66 in 274 mm 10 79 in 4 1 mm 0 16 in Figure 5 Four Slot Reconfigurable Embedded Chassis with the Controller Installed Front View with Dimensions Cooling Outline 25 4 mm 1 0 in Cooling O...

Page 8: ...m 1 43 in 19 0 mm 0 75 in 88 1 mm 3 47 in 165 1 mm 6 50 in Mounting the Chassis on a Panel Complete the following steps to mount the chassis on a panel 1 Align the chassis on the panel 2 Bolt or screw...

Page 9: ...want to mount a four slot CompactRIO chassis on a DIN rail or the NI 9915 DIN rail mount kit if you want to mount an eight slot CompactRIO chassis on a DIN rail You need one clip for mounting the cha...

Page 10: ...lip Figure 11 Attaching the DIN Rail Clip to the DIN Rail 3 2 1 1 DIN Rail Clip 2 DIN Rail 3 DIN Rail Spring 3 Press down firmly on the chassis to compress the spring until the clip locks in place on...

Page 11: ...r more information about the different connector types Complete the following steps to install a C Series I O module in the chassis 1 Make sure that no I O side power is connected to the I O module If...

Page 12: ...I O Modules from the Chassis Complete the following steps to remove a C Series I O module from the chassis 1 Make sure that no I O side power is connected to the I O module If the system is in a nonh...

Page 13: ...ory to the FPGA when the controller powers on Autoload VI on device reboot Loads the FPGA bit stream from flash memory to the FPGA when you reboot the controller either with or without cycling power R...

Page 14: ...lops 51 840 Number of 6 input LUTs 51 840 Number of DSP48 slices 25 x 18 multipliers 48 Embedded block RAM 3 456 kbits cRIO 9118 FPGA type Virtex 5 LX110 Number of flip flops 69 120 Number of 6 input...

Page 15: ...00 mW maximum cRIO 9116 5 VDC 500 mW maximum 3 3 VDC 4 600 mW maximum Total chassis power consumption 5 100 mW maximum cRIO 9118 5 VDC 500 mW max 3 3 VDC 5 400 mW max Total chassis power consumption 5...

Page 16: ...of the CompactRIO system 63 5 mm 2 5 in from the side and 25 4 mm 1 in from the rear cover of the system Storage temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 85 C Ingress protection IP40 Operating...

Page 17: ...0 2011 CSA 60079 15 2012 Note For UL and other safety certifications refer to the product label or the Online Product Certification section Electromagnetic Compatibility This product meets the requir...

Page 18: ...Our Environmental Impact web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included...

Page 19: ...ation If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration NI corporate headquarters is located at 11500 North Mopac Expressway Austin...

Page 20: ...arty legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relev...

Reviews: