![background image](http://html1.mh-extra.com/html/national-instruments/ni-9476e/ni-9476e_operating-instructions-and-specifications_3564721005.webp)
NI 9476E Operating Instructions and Specifications
|
© National Instruments
|
5
Each channel has a DO pin to which you can connect a digital input
device. The 32 digital output channels are internally referenced
to COM.
You must connect an external power supply to the NI 9476. The
power supply provides the current for the output channels. Connect
the positive lead of the power supply to the supply pin, V
sup
, and
the negative lead of the power supply to the common pin, COM.
Refer to the
Specifications
section for information about the power
supply voltage range.
Note
The V
sup
pins are internally connected. You can
connect only one external voltage supply to the device.
Caution
Do
not
remove or insert modules if the external
power supply connected to the V
sup
and COM pins is
powered on.
The NI 9476 has current sourcing outputs, meaning the DO pin is
driven to V
sup