background image

Information is subject to change without notice. Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for

information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their
respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help

»

Patents

 in your

software, the 

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

. You can find

information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer
to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the NI global trade compliance policy and how

to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS
TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S.
Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable
limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2019 National Instruments. All rights reserved.

378062A-01

August 22, 2019

Summary of Contents for NI-9252

Page 1: ...NI 9252...

Page 2: ...ication 6 Accuracy under Calibration Conditions 6 Worldwide Support and Services 7 Software Calibrating the NI 9252 requires the installation of NI DAQmx 19 1 or later on the calibration system You ca...

Page 3: ...rt for Visual Studio Reference information for NI DAQmx NET methods and NI DAQmx NET properties key concepts and a C enum to NET enum mapping table Test Equipment The following table lists the equipme...

Page 4: ...8 chassis to the system safety ground a Attach a ring lug to a 14 AWG 1 6 mm wire b Connect the ring lug to the ground terminal on the side of the NI cDAQ 9178 using the ground screw c Attach the othe...

Page 5: ...ble 2 NI 9252 AI Voltage Task Physical Channels Range Terminal Configuration cDAQMod8 AI0 7 10 5 V Differential b Configure the AI voltage channel timing according to the following NI 9252 Task Timing...

Page 6: ...equired to adjust the NI 9252 Accuracy Adjustment Complete the following procedure to adjust the accuracy performance of the NI 9252 1 Set the calibrator to Standby mode STBY 2 Connect the NI 9252 to...

Page 7: ...calibration temperature without making any adjustments by initializing an external calibration setting the C Series calibration temperature and closing the external calibration Reverification Repeat...

Page 8: ...i com services for information about the services NI offers Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you receive important...

Page 9: ...ents EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy a...