Connecting the NI 9203

The NI-9203 provides connections for 8 analog input channels.

Figure 1. NI-9203 Pinout

AI0
AI1
AI2
AI3
AI4
AI5
AI6
AI7
NC
COM

0
1
2
3
4
5
6
7
8
9

Each channel has an AI terminal to which you can connect a current signal. The

NI-9203 also has a common terminal, COM, that is internally connected to the

isolated ground reference of the module.

Overvoltage Protection

The NI-9203 provides overvoltage protection for each channel.

Note

 Refer to the NI-9203 Specifications on 

ni.com/manuals

 for more

information about overvoltage protection.

Connecting Single-Ended Current Signals

You can connect single-ended current signals to the NI-9203.

Figure 2. Connecting Single-Ended Current Signals to the NI-9203

© National Instruments

7

NI-9203 Getting Started

Summary of Contents for NI 9203

Page 1: ...NI 9203 Getting Started 2022 07 06...

Page 2: ...or Hazardous Locations 4 Electromagnetic Compatibility Guidelines 5 Special Conditions for Marine Applications 6 Preparing the Environment 6 Connecting the NI 9203 6 Overvoltage Protection 7 Connectin...

Page 3: ...s Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user...

Page 4: ...lines if you are installing the NI 9203 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connecto...

Page 5: ...he system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN 60079 15 Caution The enclosure must have a door or cover...

Page 6: ...te link Notice In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power and input output ports In addition take pre...

Page 7: ...M that is internally connected to the isolated ground reference of the module Overvoltage Protection The NI 9203 provides overvoltage protection for each channel Note Refer to the NI 9203 Specificatio...

Page 8: ...velopment self help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your N...

Reviews: