background image

 

LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle 
logo are trademarks of National Instruments Corporation. Refer to the 

Trademark Information 

at

 

ni.com/trademarks

 for other National Instruments trademarks. Other product and company 

names mentioned herein are trademarks or trade names of their respective companies. For patents 
covering National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 

in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 

at

ni.com/patents

.

© 2010 National Instruments Corporation. All rights reserved.

375519A-01

Jul10

Where to Go for Support

The National Instruments Web site is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

National Instruments corporate headquarters is located at 
11500 North Mopac Expressway, Austin, Texas, 78759-3504. 
National Instruments also has offices located around the world to help 
address your support needs. For telephone support in the United States, 
create your service request at 

ni.com/support

 and follow the calling 

instructions or dial 512 795 8248. For telephone support outside the United 
States, contact your local branch office: 

Australia 1800 300 800, Austria 43 662 457990-0, 
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599, 
Canada 800 433 3488, China 86 21 5050 9800, 
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, 
Finland 358 (0) 9 725 72511, France 01 57 66 24 24, 
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737, 
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, 
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710, 
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466, 
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, 
Poland 48 22 328 90 10, Portugal 351 210 311 210, 
Russia 7 495 783 6851, Singapore 1800 226 5886, 
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, 
Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00, 
Switzerland 41 56 2005151, Taiwan 886 02 2377 2222, 
Thailand 662 278 6777, Turkey 90 212 279 3031, 
United Kingdom 44 (0) 1635 523545

Summary of Contents for NI 9148

Page 1: ...is document describes how to connect the NI 9148 to a network and how to use the features of the NI 9148 This document also contains specifications for the NI 9148 1 LEDs 2 RJ 45 Ethernet Port 3 Power...

Page 2: ...C Series I O modules DIN rail mount kit for DIN rail mounting only Two M4 or number 10 panhead screws for panel mounting only A number 2 Phillips screwdriver Power supply Notes Visit ni com info and...

Page 3: ...ing clearance for common connectors such as the 10 terminal detachable screw terminal connector as shown in Figure 2 Figure 2 NI 9148 Bottom View with Dimensions Figure 3 NI 9148 Front View with Dimen...

Page 4: ...on Make sure that no I O modules are in the chassis before mounting it Mounting the Chassis on a Panel You can use the NI 9905 panel mount kit to mount the NI 9148 on a flat surface Complete the follo...

Page 5: ...the NI 9905 panel to the wall using the screwdriver and screws that are appropriate for the wall surface Caution Make sure that no I O modules are in the chassis before removing it from the panel 31...

Page 6: ...n a DIN rail You need one clip for mounting the chassis on a standard 35 mm DIN rail Complete the following steps to mount the chassis on a DIN rail 1 Fasten the DIN rail clip to the chassis using a n...

Page 7: ...ly on the chassis to compress the spring until the clip locks in place on the DIN rail Caution Make sure that no I O modules are in the chassis before removing it from the DIN rail Installing C Series...

Page 8: ...when you install I O modules 2 Align the I O module with an I O module slot in the chassis as shown in Figure 10 The module slots are labeled 1 to 8 left to right Figure 10 Installing an I O Module i...

Page 9: ...net cable If you need to build your own cable refer to the Cabling section for more information about Ethernet cable wiring connections Note You will configure the IP settings as described in the Conf...

Page 10: ...COMBICON connector on the front panel of the NI 9148 Caution The C terminals are internally connected to each other Powering On the NI 9148 When you apply power to the NI 9148 the chassis runs a power...

Page 11: ...is in the IP Settings section then click Apply Note For information about configuring network settings refer to the Configuring Network Settings book of the MAX Remote Systems Help In MAX click Help H...

Page 12: ...essential services required for updating configuration and installing software Push the SAFE MODE switch to the ON position if the software on the chassis is corrupted Even if the switch is not in the...

Page 13: ...n The NI 9148 indicates specific error conditions by flashing the STATUS LED a certain number of times every few seconds as shown in Table 2 Table 2 Status LED Indications Number of Flashes Indication...

Page 14: ...ition 2 Disconnect and reconnect chassis power 3 Move the IP RESET and SAFE MODE switches to the OFF position 4 Configure the IP and other network settings in MAX Note If the chassis is restored to th...

Page 15: ...egment Reconfigurable FPGA Number of logic cells 46 080 Available embedded RAM 720 kbits Power Requirements Caution You must use a UL Listed ITE power supply marked LPS with the NI 9148 Recommended po...

Page 16: ...electronics Caution Do not connect the system to signals or use for measurements within Measurement Categories II III or IV Safety Standards This product meets the requirements of the following standa...

Page 17: ...page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Electri...

Page 18: ...EC 60068 2 2 40 to 85 C Ingress protection IP 40 Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing Storage humidity IEC 60068 2 56 5 to 95 RH noncondensing Maximum altitude 2 000 m Pollution...

Page 19: ...thernet Connector Pinout Table 3 Ethernet Cable Wiring Connections Pin Connector 1 Connector 2 Normal Connector 2 Crossover 1 white orange white orange white green 2 orange orange green 3 white green...

Page 20: ...rth Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your se...