Appendix B
Timing Diagrams
©
National Instruments Corporation
B-21
Analog Output Timing Diagrams
The analog output timing can be broken into the following three sections:
•
—The timing for external signals to enter the M Series
device and be available on the internal signal buses
•
—The timing specifications of the
analog output unit itself, to and from internal signals
•
—The timing of exported signals going to the M Series
device external terminals
Figure B-22 gives an overview of analog output timing.
Figure B-22.
M Series Analog Output Timing
The following signals are used in Figure B-22 and in the following
sections:
•
Sample Clock
—This signal multiplied by the digital to analog
conversions. This signal is routed to the DAC, and in every pulse, the
DAC will perform a data conversion. This signal can come directly
from an external signal or can be the result of dividing down the
Sample Clock Timebase using the UI counter.