S Mode Functions
Chapter 5
GPIB-SCSI-A User Manual
5-38
© National Instruments Corp.
gts
(continued)
2.
Request the GPIB-SCSI-A to become Standby Controller and shadow
handshake the data on the GPIB.
Build SCSI Command Descriptor Block (CDB)
Byte 0 = 0xC7
Byte 1 = 0x00
Byte 2 = 0x00
Byte 3 = 0x01
Byte 4 = 0x00
Byte 5 = 0x00
SCSIArbitrate
SCSISelect(GPIB-SCSI-A id)
SCSICmd(CDB)
SCSIStatus(Sbyte)
SCSIMesgIn(Mbyte)
ErrorCheck