Safety

This product meets the requirements of the following standards of safety for electrical equipment 
for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Note

For UL and other safety certifications, refer to the product label or the 

Online 

Product Certification

 section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment 
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

AS/NZS CISPR 11: Group 1, Class A emissions

FCC 47 CFR Part 15B: Class A emissions

ICES-001: Class A emissions

Note

For the standards applied to assess the EMC of this product, refer to the 

Online 

Product Certification

 section.

Note

EMC compliance evaluated with a wrapback adapter module and general 

purpose I/O (GPIO) signals configured to LVTTL I/O standard, slew rate set to slow, 
and drive strength set to 6 mA. EMC compliance of other I/O standards, faster slew 
rates, and greater drive strength is not guaranteed.

CE Compliance

This product meets the essential requirements of applicable European Directives as follows:

2006/95/EC; Low-Voltage Directive (safety)

2004/108/EC; Electromagnetic Compatibility Directive (EMC)

Online Product Certification

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance 
information. To obtain product certifications and the DoC for this product, visit 

ni.com/

certification

, search by model number or product line, and click the appropriate link in the 

Certification column.

Summary of Contents for FlexRIO PXI-79 R Series

Page 1: ...PXIe 7976...

Page 2: ...FlexRIO FPGA Module Signals 8 Specifications 10 Where to Go for Support 15 How to Use Your NI FlexRIO Documentation Set Refer to the Figure 1 and Table 1 for information about how to use your NI Flex...

Page 3: ...Start Menu Contains installation instructions for your NI FlexRIO system and specifications for your FPGA module NI FlexRIO Adapter Module User Guide and Specifications Available from the Start Menu C...

Page 4: ...cent version of NI FlexRIO Adapter Module Support is available at ni com Visit ni com info and enter famsoftware as the Info Code to download the latest version of NI FlexRIO Adapter Module Support Yo...

Page 5: ...following order 1 LabVIEW Refer to the LabVIEW Release Notes for installation instructions for LabVIEW and system requirements for the LabVIEW software Refer to the LabVIEW Upgrade Notes for addition...

Page 6: ...ng the hardware For software installation information refer to Step 1 Install the Application Software and Driver Unpacking The NI FlexRIO FPGA module and the NI FlexRIO adapter module are shipped in...

Page 7: ...re the chassis 2 Identify a supported PXI PXI Express slot in the chassis Figure 4 shows the symbols that indicate the slot types in a PXI PXI Express chassis Figure 4 Symbols for PXI Express PXI Expr...

Page 8: ...screws 6 Plug in and power on the PXI PXI Express chassis Confirming That the Device Is Recognized in Measurement Automation Explorer MAX To confirm that your device is recognized complete the follow...

Page 9: ...the NI FlexRIO Adapter Module 2 Tighten the captive screws on the NI FlexRIO adapter module to secure it to the NI FlexRIO FPGA module 3 Launch LabVIEW to begin configuring your NI FlexRIO system Not...

Page 10: ...O_26_CC GPIO_26_n_CC GND GPIO_27 GPIO_27_n GND GPIO_28 GPIO_28_n GND GPIO_29 GPIO_29_n GND GND PCB Secondary Side Bank 0 PCB Primary Side GND GND GClk_SE GND GPIO_14 GPIO_14_n GND GPIO_15 GPIO_15_n GN...

Page 11: ...Hz Timebase reference sources NI PXI 795xR PXI 10 MHz PXI_CLK10 NI PXIe 796xR PXI Express 100 MHz PXIe_CLK100 Device FPGA LUTs Flip Flops DSP48 Slices 25 18 Multiplier Embedded Block RAM kbits NI PXI...

Page 12: ...nk 1 Bank 3 34 single ended per bank Compatibility Configured through the FPGA and based on the attached adapter module 1 2 V 1 5 V 1 8 V 2 5 V 3 3 V I O standards refer to www xilinx com Protection R...

Page 13: ...I Express or PXI Express hybrid slots Maximum Power Requirements2 NI PXI 795xR 5 VDC 5 2 A 3 3 VDC 5 2 A 12 V 0 5 A 12 V 0 A NI PXIe 796xR 3 3 VDC 5 3 A 12 V 2 A Physical Dimensions not including conn...

Page 14: ...ment Ambient temperature range 20 C to 70 C tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 5 to 95 noncondensing tested in accordance with IEC 60068 2 56 Note Clean...

Page 15: ...issions Note For the standards applied to assess the EMC of this product refer to the Online Product Certification section Note EMC compliance evaluated with a wrapback adapter module and general purp...

Page 16: ...C on Waste and Electronic Equipment visit ni com environment weee Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have a...

Page 17: ...product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products technology refer to the appropriate location H...

Reviews: