FP-AI-112 and cFP-AI-112

12

ni.com

Physical Characteristics

Indicators .......................................... Green 

POWER

 and 

READY

 indicators

Weight

FP-AI-112................................... 142 g (5.0 oz)
cFP-AI-112................................. 113 g (4.0 oz)

Power Requirements

Power from network module ............ 350 mW

Isolation Voltage

Channel-to-ground isolation

Continuous ................................. 250 V

rms

Installation Category II

Dielectric withstand.................... 2,300 V

rms

, 1 minute

Channel-to-channel isolation ............ None

Environmental

FieldPoint modules are intended for indoor use only. For outdoor 
use, they must be mounted inside a sealed enclosure.

Operating temperature ...................... –40 to 70 °C

Storage temperature .......................... –50 to 85 °C 

Humidity ........................................... 10 to 90% RH, 

noncondensing

Maximum altitude............................. 2,000 m; at higher altitudes 

the isolation voltage ratings 
must be lowered.

Pollution Degree ............................... 2

Summary of Contents for FieldPoint FP-AI-112

Page 1: ...c FP AI 112 is a FieldPoint analog input module with the following features 16 analog voltage input channels Eight voltage input ranges 0 1 V 0 5 V 0 10 V 60 mV 300 mV 1 V 5 V and 10 V 16 bit resoluti...

Page 2: ...lace Figure 1 Installing the FP AI 112 Installing the cFP AI 112 The cFP AI 112 mounts on a Compact FieldPoint backplane cFP BP x which provides operating power to the module Installing the cFP AI 112...

Page 3: ...ions for each of the 16 input channels and for an optional external power supply to power field devices The cFP CB x connector block provides the same connections Each channel has one input terminal V...

Page 4: ...ternal power supply and the V terminals The wiring diagrams in this document show fuses where appropriate Table 1 lists the terminal assignments for the signals associated with each channel The termin...

Page 5: ...tage source without an external power supply to one channel of the c FP AI 112 Figure 3 Voltage Source without External Power Supply Figure 4 shows how to connect a voltage source with an external pow...

Page 6: ...able for each channel The filters on the c FP AI 112 input channels are comb filters that provide notches of rejection at multiples or harmonics of a fundamental frequency You can select a fundamental...

Page 7: ...nd 5 V The update rate does not affect the rate at which the network module reads the data Set up your application so that the update rate is faster than the rate at which the network module polls the...

Page 8: ...uits that can be at hazardous potentials under normal conditions unless the product is specifically designed for such an application as is the c FP AI 112 Even though the c FP AI 112 is designed to ha...

Page 9: ...most cases Occasionally however a temporary conductivity caused by condensation must be expected Do not operate FieldPoint products in an explosive atmosphere or where there may be flammable gases or...

Page 10: ...at 500 Hz 60 mV 65 mV 3 V 25 V 300 mV 325 mV 16 V 100 V 1 V 1 04 V 40 V 300 V 5 V 5 2 V 190 V 1500 V 10 V 10 4 V 380 V 3000 V 0 1 V 0 1 04 V 20 V 300 V 0 5 V 0 5 2 V 95 V 1500 V 0 10 V 0 10 4 V 190 V...

Page 11: ...anted Accuracy at 15 to 35 C of Reading of Full Scale 60 mV 0 03 0 05 0 05 0 3 300 mV 0 03 0 015 0 05 0 1 1 V 0 03 0 008 0 05 0 04 5 V 0 03 0 005 0 05 0 02 10 V 0 03 0 005 0 05 0 02 0 1 V 0 03 0 005 0...

Page 12: ...ontinuous 250 Vrms Installation Category II Dielectric withstand 2 300 Vrms 1 minute Channel to channel isolation None Environmental FieldPoint modules are intended for indoor use only For outdoor use...

Page 13: ...s product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CAN CSA C22 2...

Page 14: ...mpliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Mechanical Dimensio...

Page 15: ...ephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada Calgary 403 274 9391...

Page 16: ...com are trademarks of National Instruments Corporation Product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments...

Reviews: