Chapter 3
Hardware Overview
3-8
©
National Instruments Corporation
In above-high-level analog triggering mode, the trigger is generated
when the signal value is greater than highValue, as shown in Figure 3-7.
LowValue is unused.
Figure 3-7.
Above-High-Level Analog Triggering Mode
In inside-region analog triggering mode, the trigger is generated when
the signal value is between the lowValue and the highValue, as shown
in Figure 3-8.
Figure 3-8.
Inside-Region Analog Triggering Mode
highValue
Trigger
highValue
Trigger
lowValue
PCI_E.book Page 8 Thursday, June 25, 1998 12:55 PM