Figure 3. cRIO-9034 Buttons
1
2
3
4
1. Power Button
2. RESET Button
3. USER1 Button
4. CMOS Reset Button
Power Button
The default behavior for the cRIO-9034 is to power on when you apply power to the controller
and power off when you press and release the power button. The behavior of the power button
can be configured in the BIOS.
If the cRIO-9034 becomes unresponsive, you can power it off by holding the power button for
4 seconds.
Related Information
Power/Wake Configuration Submenu
on page 37
RESET Button
Press the RESET button to reset the processor in the same manner as cycling power.
Troubleshooting Network Connectivity
You can use the RESET button to troubleshoot network connectivity.
Complete the following steps to reset the network adapters to default settings.
1.
Hold the RESET button for 5 seconds, and then release it to boot the controller in safe
mode and enable Console Out.
2.
Hold the RESET button again for 5 seconds to boot the controller into safe mode, enable
Console Out, and reset network adapters to default settings.
System Reset
The following figure shows the reset behavior of the cRIO-9034.
NI cRIO-9034 User Manual
|
© National Instruments
|
15