Internal Real-Time Clock
Accuracy .................................................200 ppm; 35 ppm at 25 °C
Power Requirements
Caution
You must use a UL Listed ITE power supply marked
LPS
with the
cRIO-9012/9014.
Recommended power supply..................48 W secondary,
18 VDC to 24 VDC
Power consumption
Controller only.................................6 W
Controller supplying power to
eight CompactRIO modules ............20 W
Power supply
On powerup .....................................9 to 35 V
After powerup..................................6 to 35 V
Note
The cRIO-9012/9014 is guaranteed to power up when 9 V is applied to V and C.
After powerup, it can operate on as little as 6 V.
Physical Characteristics
If you need to clean the controller, wipe it with a dry towel.
Screw-terminal wiring ............................12 to 24 AWG copper conductor
wire with 10 mm (0.39 in.) of
insulation stripped from the end
Torque for screw terminals.....................0.5 to 0.6 N · m
(4.4 to 5.3 lb · in.)
Weight ....................................................Approx. 488 g (17.2 oz)
Safety Voltages
Connect only voltages that are within these limits.
V-to-C .....................................................35 V max, Measurement
Category I
Measurement Category I is for measurements performed on circuits not
directly connected to the electrical distribution system referred to as
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com