background image

NI corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI
also has offices located around the world. For telephone support
in the United States, create your service request at 

ni.com/support

or dial 1 866 ASK MYNI (275 6964). For telephone support
outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers,
email addresses, and current events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on NI

trademarks. Other product and company names mentioned herein are trademarks or trade names
of their respective companies. For patents covering NI products/technology, refer to the
appropriate location: 

Help

»

Patents

 in your software, the 

patents.txt

 file on your media, or the

National Instruments Patent Notice

 at 

ni.com/patents

. You can find information about end-user

license agreements (EULAs) and third-party legal notices in the readme file for your NI product.
Refer to the 

Export Compliance Information

 at 

ni.com/legal/export-compliance

 for the NI

global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/
export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF
THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
U.S. Government Customers: The data contained in this manual was developed at private
expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR
52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© 2008—2015 National Instruments. All rights reserved.

374645B-01

Oct15

Summary of Contents for 9235

Page 1: ...GETTING STARTED GUIDE NI 9235 8 AI 29 4 mV V 24 Bit 10 kS s ch Simultaneous 120 Quarter Bridge Completion...

Page 2: ...Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9235 only as described in this document Cauti...

Page 3: ...measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage MAINS is a hazardous live electrical supply system that powers equipment T...

Page 4: ...ations only Follow these guidelines if you are installing the NI 9235 in a potentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconn...

Page 5: ...Ex nA IIC T4 Gc equipment under DEMKO Certificate No 07 ATEX 0626664X and is IECEx UL 14 0089X certified Each NI 9235 is marked II 3G and is suitable for use in Zone 2 hazardous locations in ambient...

Page 6: ...ility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limi...

Page 7: ...for Marine Applications Some products are Lloyd s Register LR Type Approved for marine shipboard applications To verify Lloyd s Register certification for a product visit ni com certification and sear...

Page 8: ...0068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 5 000 m Indoor use only Note Refer to the device datasheet on ni com manuals fo...

Page 9: ...t 1 2 3 4 5 6 7 8 9 10 11 12 EXC1 AI1 RC1 EXC3 AI3 RC3 EXC5 AI5 RC5 EXC7 AI7 RC7 EXC0 AI0 RC0 EXC2 AI2 RC2 EXC4 AI4 RC4 EXC6 AI6 RC6 13 14 15 16 17 18 19 20 21 22 23 24 NI 9235 Getting Started Guide N...

Page 10: ...stimulus AI Measures the bridge voltage RC Provides the quarter bridge completion Connecting a Quarter Bridge Sensor You can connect quarter bridge sensors to the NI 9235 Figure 2 Connecting a Quarte...

Page 11: ...of an identical wire type and gauge Connect the AI terminal directly at the sensor instead of shorting AI to RC directly at the terminals Connecting Wires to a Spring Terminal Connector Complete the f...

Page 12: ...ert the screwdriver into a spring clamp activation slot to open the corresponding connector terminal 2 Press a wire into the open connector terminal 3 Remove the screwdriver from the activation slot t...

Page 13: ...pplication Connections If your application is subject to high vibration NI recommends that you use the NI 9965 backshell kit to protect connections to the NI 9235 NI 9235 Getting Started Guide Nationa...

Page 14: ...tware CompactRIO NI CompactDAQ RELATED INFORMATION C Series Documentation Resources ni com info cseriesdoc Services ni com services NI 9235 Datasheet NI RIO Help LabVIEW FPGA Help NI 9235 Datasheet NI...

Page 15: ...duct Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council o...

Page 16: ...cts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information a...

Reviews: